Source author record

Brad Sawatzky

Brad Sawatzky appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2026arXiv

The BigBite Calorimeter for the Super Bigbite Spectrometer Program at Jefferson Lab

We report features of the design, construction, installation, and performance of the BigBite Calorimeter (BBCal), a lead-glass electromagnetic calorimeter constructed as part of the BigBite Spectrometer (BBS), which served as the electron arm for the Super Bigbite Spectrometer (SBS) program of high-precision neutron electromagnetic form factor measurements in Hall A at Jefferson Lab. As a total-absorption calorimeter, BBCal provided the primary electron trigger for BBS, detecting (quasi-) elastically scattered electrons in the 1-4 GeV energy range with an energy resolution of approximately 6.2%, position resolution of 1.2 cm, and timing resolution of 0.5 ns.

preprint2016arXiv

The Proton Radius from Electron Scattering Data

[Background] The proton charge radius extracted from recent muonic hydrogen Lamb shift measurements is significantly smaller than that extracted from atomic hydrogen and electron scattering measurements. [Purpose] In an attempt to understand the discrepancy, we review high-precision electron scattering results from Mainz, Jefferson Lab, Saskatoon and Stanford. [Method] We make use of stepwise regression techniques using the $F$-test as well as the Akaike information criterion to systematically determine the predictive variables to use for a given set and range of electron scattering data as well as to provide multivariate error estimates. [Results] Starting with the precision, low four-momentum transfer ($Q^2$) data from Mainz (1980) and Saskatoon (1974), we find that a stepwise regression of the Maclaurin series using the $F$-test as well as the Akaike information criterion justify using a linear extrapolation which yields a value for the proton radius that is consistent with the result obtained from muonic hydrogen measurements. Applying the same Maclaurin series and statistical criteria to the 2014 Rosenbluth results on $G_E$ from Mainz, we again find that the stepwise regression tends to favor a radius consistent with the muonic hydrogen radius but produces results that are extremely sensitive to the range of data included in the fit. Making use of the high-$Q^2$ data on $G_E$ to select functions which extrapolate to high $Q^2$, we find that a Padé ($N=M=1$) statistical model works remarkably well, as does a dipole function with a 0.84 fm radius, $G_E(Q^2) = ( 1 + Q^2/0.66\,\mathrm{GeV}^2)^{-2}$. [Conclusions] From this statistical analysis, we conclude that the electron scattering result and the muonic hydrogen result are consistent. It is the atomic hydrogen results that are the outliers.

preprint2015arXiv

A Threshold Gas Čerenkov Detector for the Spin Asymmetries of the Nucleon Experiment

We report on the design, construction, commissioning, and performance of a threshold gas Čerenkov counter in an open configuration, which operates in a high luminosity environment and produces a high photo-electron yield. Part of a unique open geometry detector package known as the Big Electron Telescope Array, this Čerenkov counter served to identify scattered electrons and reject produced pions in an inclusive scattering experiment known as the Spin Asymmetries of the Nucleon Experiment E07-003 at the Thomas Jefferson National Accelerator Facility (TJNAF) also known as Jefferson Lab. The experiment consisted of a measurement of double spin asymmetries $A_{\parallel}$ and $A_{\perp}$ of a polarized electron beam impinging on a polarized ammonia target. The Čerenkov counter's performance is characterised by a yield of about 20 photoelectrons per electron or positron track. Thanks to this large number of photoelectrons per track, the Čerenkov counter had enough resolution to identify electron-positron pairs from the conversion of photons resulting mainly from $π^0$ decays.