Researcher profile

Bo-xiang Yu

Bo-xiang Yu contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2015arXiv

Preliminary study of light yield dependence on LAB liquid scintillator composition

Liquid scintillator (LS) will be adopted as the detector material in JUNO (Jiangmen Underground Neutrino Observatory). The energy resolution requirement of JUNO is 3%, which has never previously been reached. To achieve this energy resolution, the light yield of liquid scintillator is an important factor. PPO (the fluor) and bis-MSB (the wavelength shifter) are the two main materials dissolved in LAB. To study the influence of these two materials on the transmission of scintillation photons in LS, 25 and 12 cm-long quartz vessels were used in a light yield experiment. LS samples with different concentration of PPO and bis-MSB were tested. At these lengths, the light yield growth is not obvious when the concentration of PPO is higher than 4 g/L. The influence from bis-MSB becomes insignificant when its concentration is higher than 8 mg/L. This result could provide some useful suggestions for the JUNO LS.

preprint2014arXiv

Aging research of the LAB-based liquid scintillator in stainless steel container

Stainless steel is the material used for the storage vessels and piping systems of LAB-based liquid scintillator in JUNO experiment. Aging is recognized as one of the main degradation mechanisms affecting the properties of liquid scintillator. LAB-based liquid scintillator aging experiments were carried out in different material of containers (type 316 and 304 stainless steel and glass) at two different temperature (40 and 25 degrees Celsius). For the continuous liquid scintillator properties tests, the light yield and the absorption spectrum are nearly the same as that of the unaged one. The attenuation length of the aged samples is 6%~12% shorter than that of the unaged one. But the concentration of element Fe in the LAB-based liquid scintillator does not show a clear change. So the self aging has small effect on liquid scintillator, as well as the stainless steel impurity quenching. Type 316 and 304 stainless steel can be used as LAB-based liquid scintillator vessel, transportation pipeline material.

preprint2014arXiv

Measurement of the liquid scintillator nonlinear energy response to electron

Nonlinearity of the liquid scintillator energy response is a key to measuring the neutrino energy spectrum in reactor neutrino experiments such as Daya Bay and JUNO. We measured in laboratory the nonlinearity of the Linear Alkyl Benzene based liquid scintillator, which is used in Daya Bay and will be used in JUNO, via Compton scattering process. By tagging the scattered gamma from the liquid scintillator sample simultaneously at seven angles, the instability of the system was largely cancelled. The accurately measured nonlinearity will improve the precision of the $θ_{13}$, $Δm^2$, and reactor neutrino spectrum measurements at Daya Bay.

preprint2011arXiv

Experimental study of THGEM detector with mini-rim

The gas gain and energy resolution of single and double THGEM detectors (5{\times}5cm2 effective area) with mini-rims (rim is less than 10μm) were studied. The maximum gain can reach 5{\times}103 and 2{\times}105 for single and double THGEM respectively, while the energy resolution of 5.9 keV X-ray varied from 18% to 28% for both single and double THGEM detectors of different hole sizes and thicknesses.All the experiments were investigated in mixture of noble gases(argon,neon) and small content of other gases(iso-butane,methane) at atmospheric pressure.