Published work

7 published item(s)

preprint2020arXiv

Measuring the length of stretched wires with a avalanche oscillator

We measure the length of stretched wire pairs by using them as the delay line pulse shaping element in an avalanche oscillator. The circuitry and method are extremely simple, and insensitive to oscillator supply voltage, to the particular transistor (2N3904) used and to wire tension. Rudimentary tests with simulated broken wires show that these can be detected easily. It remains to be seen whether the technique will work at scale with realistic wire planes, but it should be at least as good as reflecting short pulses.

preprint2015arXiv

On the nuclear halo of a proton pencil beam stopping in water

The dose distribution of a pencil beam in water consists of a core, a halo, an aura and (possibly) spray. The core is due to primary protons which suffer multiple Coulomb scattering (MCS) and slow down by multiple collisions with atomic electrons (Bethe-Bloch theory). The halo is due to charged secondaries, many of them protons, from elastic interactions with H, elastic and inelastic interactions with O, and nonelastic interactions with O. We show that the halo radius is roughly one third of the beam range. The aura is due to neutral secondaries (neutrons and gamma rays). Spray denotes dose, avoidable in principle, coming in from the beam line. We have measured the absolute dose at 177 MeV using a test beam in a water tank. The beam monitor was a PPIC 'proton counter' and the field IC a dose calibrated Exradin T1. We took depth-dose scans at ten displacements from the beam axis ranging from 0 to 10 cm. The dose spans five orders of magnitude, and the transition from halo to aura is obvious. We present model-dependent (MD) and model-independent (MI) fits to these data. The MD fit has 25 parameters, and the goodness of fit (rms (measurement/fit) - 1) is 15%. The MI fit uses cubic spline fits in depth and radius. The goodness of fit is 9%. This fit is more portable and conceptually simpler. We discuss the prevalent parameterization of the core/halo originated by the PSI group. We argue that its use of T(w), a mass stopping power which includes energy deposited by nuclear secondaries, is incorrect. The electromagnetic (Bethe-Bloch) mass stopping power should be used instead. In consequence, 'Bragg peak chamber' measurements and associated corrections are, in our view, irrelevant. Furthermore, using T(w) leads to spurious excess dose on the axis of the core around midrange, which may be significant in fields involving relatively few pencil beams.

preprint2015arXiv

Validation of nuclear models in Geant4 using the dose distribution of a 177 MeV proton pencil beam

A proton pencil beam is associated with a surrounding low-dose envelope, originating from nuclear interactions. It is important for treatment planning systems to accurately model this envelope when performing dose calculations for pencil beam scanning treatments, and Monte Carlo (MC) codes are commonly used for this purpose. This work aims to validate the nuclear models employed by the Geant4 MC code, by comparing the simulated absolute dose distribution to a recent experiment of a 177 MeV proton pencil beam stopping in water. Striking agreement is observed over five orders of magnitude, with both the shape and normalisation well modelled. The normalisations of two depth dose curves are lower than experiment, though this could be explained by an experimental positioning error. The Geant4 neutron production model is also verified in the distal region. The entrance dose is poorly modelled, suggesting an unaccounted upstream source of low-energy protons. Recommendations are given for a follow-up experiment which could resolve these issues.

preprint2014arXiv

Nuclear halo of a 177 MeV proton beam in water: theory, measurement and parameterization

The dose distribution of a monoenergetic pencil beam in water consists of an electromagnetic "core", a "halo" from charged nuclear secondaries, and a much larger "aura" from neutral secondaries. These regions overlap, but each has distinct spatial characteristics. We have measured the core/halo using a 177MeV test beam offset in a water tank. The beam monitor was a fluence calibrated plane parallel ionization chamber (IC) and the field chamber, a dose calibrated Exradin T1, so the dose measurements are absolute (MeV/g/p). We performed depth-dose scans at ten displacements from the beam axis ranging from 0 to 10cm. The dose spans five orders of magnitude, and the transition from halo to aura is clearly visible. We have performed model-dependent (MD) and model-independent (MI) fits to the data. The MD fit separates the dose into core, elastic/inelastic nuclear, nonelastic nuclear and aura terms, and achieves a global rms measurement/fit ratio of 15%. The MI fit uses cubic splines and the same ratio is 9%. We review the literature, in particular the use of Pedroni's parametrization of the core/halo. Several papers improve on his Gaussian transverse distribution of the halo, but all retain his T(w), the radial integral of the depth-dose multiplying both the core and halo terms and motivating measurements with large "Bragg peak chambers" (BPCs). We argue that this use of T(w), which by its definition includes energy deposition by nuclear secondaries, is incorrect. T(w) should be replaced in the core term, and in at least part of the halo, by a purely electromagnetic mass stopping power. BPC measurements are unnecessary, and irrelevant to parameterizing the pencil beam.

preprint2014arXiv

Skewness and kurtosis as measures of range mixing in time resolved diode dosimetry

Technical Note describing studies, in 2011, of time resolved diode dosimetry in an anthropomorphic phantom at the Francis H. Burr Proton Therapy Center, Massachusetts General Hospital, Boston, MA. This technique measures the water equivalent path length (WEPL) to a diode dosimeter with sub-millimeter precision, using very little dose. It may allow one to use the proton stopping point (otherwise too uncertain) to cut between tissue to be treated and tissue to be spared, in cases (such as the prostate) where a diode can be placed in a cavity (the rectum) distal to the target. A potential problem is range mixing, where (because of scattering) protons may arrive at a diode with different energy-loss histories. The WEPL reported by such a diode is meaningless and must be ignored. We therefore use an array of diodes, of which some are likely to be at more favorable locations. In addition to the overall analysis of time resolved data, this Note describes in detail how range mixed diodes can be identified by looking at the skewness and kurtosis of the time dependent signal.

preprint2012arXiv

Techniques of Proton Radiotherapy: Transport Theory

These are notes for the lecture on Transport Theory in a one-week intensive course, "Techniques of Proton Radiotherapy". Topics are: Phase space diagrams: model beam line-effect of a scatterer-effect of a drift-the beam ellipse-phase space diagrams for the model beam line-emittance change in a drift-emittance change in a scatterer-phase space for a more realistic beam line-summary Miscellaneous topics: review of Gaussians-the Gaussian approximation to multiple Coulomb scattering (MCS)-relativistic single particle kinematics-completing the square-scattering power Fermi-Eyges theory: history-the basic theory-the beam ellipse-drawing the ellipse given the moments-ellipse examples-transporting the beam ellipse through a slab-emittance change in a drift-emittance change in a scatterer-differential form of the transport equations-equivalent sources-beam contained in the beam ellipse-summary Beam spreading in matter: theory of Preston and Koehler-generalization to heavy ions-experimental tests (Preston and Koehler, Phillips, Wong et al.)-summary Analytical geometry of the ellipse (appendix): tilted ellipse-transformation to principal frame-summary and explicit procedures-area enclosed by the ellipse

preprint2009arXiv

On the scattering power of radiotherapy protons

Scattering power (T = d/dx of mean squared multiple Coulomb scattering (MCS) angle), as used in proton transport theory, is properly viewed as a differential description of the Gaussian approximation to MCS theories such as Moliere's. That is, we seek a function T which, when integrated over a finite slab, will recover the Moliere/Fano/Hanson angle for that slab. To be accurate, T must include a single scattering correction, which means mathematically it must be nonlocal, depending on how much MCS has taken place as well as the energy and scattering material at the POI. We review five formulas for T and introduce a sixth, testing each against the Moliere/Fano/Hanson prediction as well as experimental data. We discuss how sensitive some practical problems are to the choice of T. That choice is probably most important for general Monte Carlo codes, which are expected to address a wide variety of problems.