Source author record

Benjamin Dueck

Benjamin Dueck appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

1works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2015arXiv

Optical diffraction for measurements of nano-mechanical bending

Micromechanical transducers such as cantilevers for AFM often rely on optical readout methods that require illumination of a specific region of the microstructure. Here we explore and exploit the diffraction effects that have been previously neglected when modeling cantilever bending measurement techniques. The illumination of a cantilever end causes an asymmetric diffraction pattern at the photodetector that significantly affects the calibration of the signal in the popular optical beam deflection technique (OBDT). Conditions for optimized linear signals that avoid detection artifacts conflict with small numerical aperture illumination and narrow cantilevers which are softer and therefore more sensitive. Embracing diffraction patterns as a physical measurable allows a richer detection technique that decouples measurements of tilt and curvature and simultaneously relaxes the requirements on the alignment of illumination and detector. We show analytical results, numerical simulations and physiologically relevant experimental data demonstrating the usefulness of these diffraction features. We offer experimental design guidelines and identify and quantify possible sources of systematic error of up to 10% in OBDT. We demonstrate a new nanometre resolution detection method that can replace OBDT, where Frauenhofer and Bragg diffraction effects from finite sized and patterned cantilevers are exploited. Such effects are readily generalized to arrays, and allow transmission detection of mechanical curvature, enabling in-line instruments. In particular, a cantilever with a periodic array of slots produces Bragg peaks which can be analyzed to deduce the cantilever curvature. We highlight the comparative advantages over OBDT by detecting molecular activity of antibiotic Vancomycin, with an RMS noise equivalent to less than $2.5 μM$ (1.5 nm), as example of possible multi-maker bio-assays.