Researcher profile

Bei Xu

Bei Xu contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Feeder Microgrid Management on an Active Distribution System during a Severe Outage

Forming a microgrid on a distribution system with large scale outage after a severe weather event is emerging as a viable solution to improve resiliency at the distribution level. This option becomes more attractive when the distribution system has high levels of distributed PV. The management of such feeder-level microgrid has however many challenges, such as limited resources that can be deployed on the feeder quickly, and the limited real-time monitoring and control on the distribution system. Effective use of the distributed PV is also challenging as they are not monitored and controlled. To handle these challenges, the paper proposes a 2-stage hierarchical energy management scheme to securely operate these feeder level micorgrids. The first stage of the scheme solves a sequential rolling optimization problem to optimally schedule the main resources (such as a mobile diesel generator and battery storage unit). The second stage adopts a dispatching scheme for the main resources to adjust the stage-1 set-points closer to real- time. The proposed scheme has unique features to assure that the scheme is robust under highly varying operating conditions with limited system observability: (i) an innovative PV forecast error adjustment and a dynamic reserve adjustment scheme to handle the extreme uncertainty on PV power output, and (ii) an intelligent fuel management scheme to assure that the resources are utilized optimally over the multiple days of the restoration period. The proposed algorithm is tested on sample system with real-time data. The results show that the proposed scheme performs well in maximizing service to loads by effective use of all the resources and by properly taking into account the challenging operating conditions.

preprint2022arXiv

SA-HMTS: A Secure and Adaptive Hierarchical Multi-timescale Framework for Resilient Load Restoration Using A Community Microgrid

Distribution system integrated community microgrids (CMGs) can partake in restoring loads during extended duration outages. At such times, the CMG is challenged with limited resource availability, absence of robust grid support, and heightened demand-supply uncertainty. This paper proposes a secure and adaptive three-stage hierarchical multi-timescale framework for scheduling and real-time (RT) dispatch of CMGs with hybrid PV systems to address these challenges. The framework enables the CMG to dynamically expand its boundary to support the neighboring grid sections and is adaptive to the changing forecast error impacts. The first stage solves a stochastic extended duration scheduling (EDS) problem to obtain referral plans for optimal resource rationing. The intermediate near-real-time (NRT) scheduling stage updates the EDS schedule closer to the dispatch time using newly obtained forecasts, followed by the RT dispatch stage. To make the dispatch decisions more secure and robust against forecast errors, a novel concept called delayed recourse is proposed. The methodology is evaluated via numerical simulations on a modified IEEE 123-bus system and validated using OpenDSS/hardware-in-loop simulations. The results show superior performance in maximizing load supply and continuous secure CMG operation under numerous operating scenarios.