Source author record

Balthasar T. Indermuehle

Balthasar T. Indermuehle appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
3topics
3close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2014arXiv

A Phase Dependent Comparison of the Velocity Parameters of SiO v=1, J=1-0 and J=2-1 Maser Emission in Long Period Variables

We have examined the relationship between the velocity parameters of SiO masers and the phase of the long period variable stars (LPVs) from which the masers originate. The SiO spectra from the v=1, J=1-0 (43.122 GHz; hereafter $J_{1\rightarrow0}$) and the v=1, J=2-1 (86.2434 GHz; hereafter $J_{2\rightarrow1}$) transitions have been measured using the Mopra Telescope of the Australia Telescope National Facility. One hundred twenty one sources have been observed including 47 LPVs contained in the American Association of Variable Star Observer Bulletin (2011). The epoch of maxima and the periods of the LPVs are well studied. This database of spectra allows for phase dependent comparisons and analysis not previously possible with such a large number of sources observed almost simultaneously in the two transitions over a time span of several years. The velocity centroids ($VCs$) and velocity ranges of emission ($VRs$) have been determined and compared for the two transitions as a function of phase. No obvious phase dependence has been determined for the $VC$ or $VR$. The results of this analysis are compared with past observations and existing SiO maser theory.

preprint2014arXiv

Millimetre-wave Site Characteristics at the Australia Telescope Compact Array

We present a millimetre-wave site characterisation for the Australia Telescope Compact Array (ATCA) based on nearly 9 years of data from a seeing monitor operating at this facility. The seeing monitor, which measures the phase fluctuations in the signal from a geosynchronous satellite over a 230\,m baseline caused by water vapour fluctuations along their sight lines, provides an almost gapless record since 2005, with high time resolution. We determine the root mean square (rms) of the path length variations as a function of time of day and season. Under the assumption of the "frozen screen" hypothesis, we also determine the Kolomogorov exponent, $α$, for the turbulence and the phase screen speed. From these, we determine the millimetre-wave seeing at $λ= 3.3$\,mm. Based on the magnitude of the rms path length variations, we estimate the expected fraction of the available observing time when interferometry could be successfully conducted using the ATCA, as a function of observing frequency and antenna baseline, for the time of day and the season. We also estimate the corresponding observing time fractions when using the water vapour radiometers (WVRs) installed on the ATCA in order to correct for the phase fluctuations occurring during the measurement of an astronomical source.

preprint2013arXiv

Water Vapour Radiometers for the Australia Telescope Compact Array

We have developed Water Vapour Radiometers (WVRs) for the Australia Telescope Compact Array (ATCA) that are capable of determining signal path length fluctuations by virtue of measuring small temperature fluctuations in the atmosphere using the 22.2 GHz water vapour line for each of the six antennae. By measuring the line of sight variations of the water vapour, the induced path excess and thus the phase delay can be estimated and corrections can then be applied during data reduction. This reduces decorrelation of the source signal. We demonstrate how this recovers the telescope's efficiency as well as how this improves the telescope's ability to use longer baselines at higher frequencies, thereby resulting in higher spatial resolution. A description of the WVR hardware design, their calibration and water vapour retrieval mechanism is given.