Source author record

Baha Sakar

Baha Sakar appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2026arXiv

On the influence of reference sample properties on magnetic force microscopy calibrations

Magnetic force microscopy (MFM) allows the characterization of magnetic stray field distributions with high sensitivity and spatial resolution. Based on a suitable calibration procedure, MFM can also yield quantitative magnetic field values. This process typically involves measuring a reference sample to determine the distribution of the tip's stray field or stray field gradient at the sample surface. This distribution is called the tip transfer function (TTF) and is derived through regularized deconvolution in Fourier space. The properties of the reference sample and the noise characteristics of the detection system significantly influence the derived TTF, thereby limiting its validity range. In a recent study, the tip stray field distribution, and hence the TTF, of an MFM tip was independently measured in real space using a nitrogen vacancy center as a quantum sensor, revealing considerable discrepancies with the reference-sample-based TTF. Here, we analyze the influence of the feature distribution of the reference sample and the MFM measurement parameters on the resulting TTF. We explain the observed differences between quantum-calibrated stray field distributions and the classical approach by attributing them to a loss of information due to missing or suppressed spectral components. Furthermore, we emphasize the importance of the spectral coverage of the TTF. Our findings indicate that for high-quality reconstruction of the stray field of a sample under test (SUT), it is more critical to ensure a strong overlap of frequency components between the reference sample and the SUT than to achieve an accurate real-space reconstruction of the tip stray field distribution.

preprint2022arXiv

A Ti/Pt/Co multilayer stack for transfer function based magnetic force microscopy calibrations

Magnetic force microscopy is a widespread technique for imaging magnetic structures with a resolution of some 10 nanometers. MFM can be calibrated to obtain quantitative spatially resolved magnetization data in units of A/m by determining the calibrated point spread function of the instrument, its instrument calibration function (ICF), from a measurement of a well-known reference sample. Beyond quantifying the MFM data, a deconvolution of the MFM image data with the ICF also corrects the smearing caused by the finite width of the MFM tip stray field distribution. However, the quality of the calibration depends critically on the calculability of the magnetization distribution of the reference sample. Here, we discuss a Ti/Pt/Co multilayer stack that shows a stripe domain pattern as a suitable reference material. A precise control of the fabrication process, combined with a characterization of the sample micromagnetic parameters, allows reliable calculation of the sample's magnetic stray field, proven by a very good agreement between micromagnetic simulations and qMFM measurements. A calibrated qMFM measurement using the Ti/Pt/Co stack as a reference sample is shown and validated, and the application area for quantitative MFM measurements calibrated with the Ti/Pt/Co stack is discussed

preprint2021arXiv

Quantum calibrated magnetic force microscopy

We report the quantum calibration of a magnetic force microscope (MFM) by measuring the two-dimensional magnetic stray field distribution of the MFM tip using a single nitrogen vacancy (NV) center in diamond. From the measured stray field distribution and the mechanical properties of the cantilever a calibration function is derived allowing to convert MFM images to quantum calibrated stray field maps. This novel approach overcomes limitations of prior MFM calibration schemes and allows quantum calibrated nanoscale stray field measurements in a field range inaccessible to scanning NV magnetometry. Quantum calibrated measurements of a stray field reference sample allow its use as a transfer standard, opening the road towards fast and easily accessible quantum traceable calibrations of virtually any MFM.