Source author record

B. W. Sleaford

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

1works
1topics
4close collaborators

Published work

1 publications

preprint2014arXiv

A structural evaluation of the tungsten isotopes via thermal neutron capture

Total radiative thermal neutron-capture γγ-ray cross sections for the 182,183,184,186^{182,183,184,186}W isotopes were measured using guided neutron beams from the Budapest Research Reactor to induce prompt and delayed γγ rays from elemental and isotopically-enriched tungsten targets. These cross sections were determined from the sum of measured γγ-ray cross sections feeding the ground state from low-lying levels below a cutoff energy, Ecrit_{\rm crit}, where the level scheme is completely known, and continuum γγ rays from levels above Ecrit_{\rm crit}, calculated using the Monte Carlo statistical-decay code DICEBOX. The new cross sections determined in this work for the tungsten nuclides are: σ0(182W)=20.5(14)σ_{0}(^{182}{\rm W}) = 20.5(14) b and σ11/2+(183Wm,5.2s)=0.177(18)σ_{11/2^{+}}(^{183}{\rm W}^{m}, 5.2 {\rm s}) = 0.177(18) b; σ0(183W)=9.37(38)σ_{0}(^{183}{\rm W}) = 9.37(38) b and σ5−(184Wm,8.33μs)=0.0247(55)σ_{5^{-}}(^{184}{\rm W}^{m}, 8.33 μ{\rm s}) = 0.0247(55) b; σ0(184W)=1.43(10)σ_{0}(^{184}{\rm W}) = 1.43(10) b and σ11/2+(185Wm,1.67min)=0.0062(16)σ_{11/2^{+}}(^{185}{\rm W}^{m}, 1.67 {\rm min}) = 0.0062(16) b; and, σ0(186W)=33.33(62)σ_{0}(^{186}{\rm W}) = 33.33(62) b and σ9/2+(187Wm,1.38μs)=0.400(16)σ_{9/2^{+}}(^{187}{\rm W}^{m}, 1.38 μ{\rm s}) = 0.400(16) b. These results are consistent with earlier measurements in the literature. The 186^{186}W cross section was also independently confirmed from an activation measurement, following the decay of 187^{187}W, yielding values for σ0(186W)σ_{0}(^{186}{\rm W}) that are consistent with our prompt γγ-ray measurement. The cross-section measurements were found to be insensitive to choice of level density or photon strength model, and only weakly dependent on Ecrit_{\rm crit}. Total radiative-capture widths calculated with DICEBOX showed much greater model dependence, however, the recommended values could be reproduced with selected model choices. The decay schemes for all tungsten isotopes were improved in these analyses.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.