Source author record

B. Schumm

B. Schumm appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

11works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

11 published item(s)

preprint2022arXiv

PIONEER: Studies of Rare Pion Decays

A next-generation rare pion decay experiment, PIONEER, is strongly motivated by several inconsistencies between Standard Model (SM) predictions and data pointing towards the potential violation of lepton flavor universality. It will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles even if their masses are at very high scales. Measurement of the charged-pion branching ratio to electrons vs. muons $R_{e/μ}$ is extremely sensitive to new physics effects. At present, the SM prediction for $R_{e/μ}$ is known to 1 part in $10^4$, which is 15 times more precise than the current experimental result. An experiment reaching the theoretical accuracy will test lepton flavor universality at an unprecedented level, probing mass scales up to the PeV range. Measurement of pion beta decay, $π^+\to π^0 e^+ ν(γ)$, with 3 to 10-fold improvement in sensitivity, will determine $V_{ud}$ in a theoretically pristine manner and test CKM unitarity, which is very important in light of the recently emerged tensions. In addition, various exotic rare decays involving sterile neutrinos and axions will be searched for with unprecedented sensitivity. The experiment design benefits from experience with the recent PIENU and PEN experiments at TRIUMF and the Paul Scherrer Institut (PSI). Excellent energy and time resolutions, greatly increased calorimeter depth, high-speed detector and electronics response, large solid angle coverage, and complete event reconstruction are all critical aspects of the approach. The PIONEER experiment design includes a 3$π$ sr 25 radiation length calorimeter, a segmented low gain avalanche detector stopping target, a positron tracker, and other detectors. Using intense pion beams, and state-of-the-art instrumentation and computational resources, the experiments can be performed at the PSI ring cyclotron.

preprint2022arXiv

Testing Lepton Flavor Universality and CKM Unitarity with Rare Pion Decays in the PIONEER experiment

The physics motivation and the conceptual design of the PIONEER experiment, a next-generation rare pion decay experiment testing lepton flavor universality and CKM unitarity, are described. Phase I of the PIONEER experiment, which was proposed and approved at Paul Scherrer Institut, aims at measuring the charged-pion branching ratio to electrons vs.\ muons, $R_{e/μ}$, 15 times more precisely than the current experimental result, reaching the precision of the Standard Model (SM) prediction at 1 part in $10^4$. Considering several inconsistencies between the SM predictions and data pointing towards the potential violation of lepton flavor universality, the PIONEER experiment will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles up to the PeV mass scale. The later phases of the PIONEER experiment aim at improving the experimental precision of the branching ratio of pion beta decay (BRPB), $π^+\to π^0 e^+ ν(γ)$, currently at $1.036(6)\times10^{-8}$, by a factor of three (Phase II) and an order of magnitude (Phase III). Such precise measurements of BRPB will allow for tests of CKM unitarity in light of the Cabibbo Angle Anomaly and the theoretically cleanest extraction of $|V_{ud}|$ at the 0.02\% level, comparable to the deduction from superallowed beta decays.

preprint2021arXiv

A new approach to achieving high granularity for silicon diode detectors with impact ionization gain

Low Gain Avalanche Diodes (LGADs) are thin (20-50 $μm$)silicon di ode sensors with modest internal gain (typically 5 to 50) and exceptional time resolution (17 $ps$ to 50 $ps$). However, the granularity of such devices is limited to the millimeter scale due to the need to include protection structures at the boundaries of the readout pads to avoid premature breakdown due to large local electric fields. In this paper we present a new approach -- the Deep-Junction LGAD (DJ-LGAD) -- that decouples the high-field gain region from the readout plane. This approach is expected to improve the achievable LGAD granularity to the tens-of-micron scale while maintaining direct charge collection on the segmented electrodes.

preprint2021arXiv

Potential for Improved Time Resolution Using Very Thin Ultra-Fast Silicon Detectors (UFSDs)

Ultra-Fast Silicon Detectors (UFSDs) are n-in-p silicon detectors that implement moderate gain (typically 5 to 25) using a thin highly doped p++ layer between the high resistivity p-bulk and the junction of the sensor. The presence of gain allows excellent time measurement for impinging minimum ionizing charged particles. An important design consideration is the sensor thickness, which has a strong impact on the achievable time resolution. We present the result of measurements for LGADs of thickness between 20 micro-m and 50 micro-m. The data are fit to a formula that captures the impact of both electronic jitter and Landau fluctuations on the time resolution. The data illustrate the importance of having a saturated electron drift velocity and a large signal-to-noise in order to achieve good time resolution. Sensors of 20 micro-m thickness offer the potential of 10 to 15 ps time resolution per measurement, a significant improvement over the value for the 50 micro-m sensors that have been typically used to date.

preprint2020arXiv

Experimental Study of Acceptor Removal in UFSD

The performance of the Ultra-Fast Silicon Detectors (UFSD) after irradiation with neutrons and protons is compromised by the removal of acceptors in the thin layer below the junction responsible for the gain. This effect is tested both with C-V measurements of the doping concentration and with measurements of charge collection using charged particles. We find a perfect linear correlation between the bias voltage to deplete the gain layer determined with C-V and the bias voltage to collect a defined charge, measured with charge collection. An example for the usefulness of this correlation is presented.

preprint2020arXiv

Layout and Performance of HPK Prototype LGAD Sensors for the High-Granularity Timing Detector

The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology will cover the pseudo-rapidity region of $2.4<|η|<4.0$ with two end caps on each side and a total area of 6.4 $m^2$. The timing performance can be improved by implanting an internal gain layer that can produce signal with a fast rising edge, which improve significantly the signal-to-noise ratio. The required average timing resolution per track for a minimum-ionising particle is 30 ps at the start and 50 ps at the end of the HL-LHC operation. This is achieved with several layers of LGAD. The innermost region of the detector would accumulate a 1 MeV-neutron equivalent fluence up to $2.5 \times 10^{15} cm^{-2}$ before being replaced during the scheduled shutdowns. The addition of this new detector is expected to play an important role in the mitigation of high pile-up at the HL-LHC. The layout and performance of the various versions of LGAD prototypes produced by Hamamatsu (HPK) have been studied by the ATLAS Collaboration. The breakdown voltages, depletion voltages, inter-pad gaps, collected charge as well as the time resolution have been measured and the production yield of large size sensors has been evaluated.

preprint2020arXiv

Radiation Campaign of HPK Prototype LGAD sensors for the High-Granularity Timing Detector (HGTD)

We report on the results of a radiation campaign with neutrons and protons of Low Gain Avalanche Detectors (LGAD) produced by Hamamatsu (HPK) as prototypes for the High-Granularity Timing Detector (HGTD) in ATLAS. Sensors with an active thickness of 50~$μ$m were irradiated in steps of roughly 2$\times$ up to a fluence of $3\times10^{15}~\mathrm{n_{eq}cm^{-2}}$. As a function of the fluence, the collected charge and time resolution of the irradiated sensors will be reported for operation at $-30^{\circ}$.

preprint2015arXiv

Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector

Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sensor are presented. A deconvolution method is successfully applied, and a comparison of the measured shower shape as a function of the absorber depth with a Monte-Carlo simulation is given.

preprint2014arXiv

ECFA Detector R&D Panel, Review Report

Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 10$^{-3}$ at the ILC and 10$^{-2}$ at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The intensity and the spatial shape of these depositions will provide a fast luminosity estimate, as well as determination of beam parameters. The sensors of this calorimeter must be radiation-hard. Both devices will improve the e.m. hermeticity of the detector in the search for new particles. Finely segmented and very compact electromagnetic calorimeters will match these requirements. Due to the high occupancy, fast front-end electronics will be needed. Monte Carlo studies were performed to investigate the impact of beam-beam interactions and physics background processes on the luminosity measurement, and of beamstrahlung on the performance of BeamCal, as well as to optimise the design of both calorimeters. Dedicated sensors, front-end and ADC ASICs have been designed for the ILC and prototypes are available. Prototypes of sensor planes fully assembled with readout electronics have been studied in electron beams.

preprint2011arXiv

Development of Readout Interconnections for the Si-W Calorimeter of SiD

The SiD collaboration is developing a Si-W sampling electromagnetic calorimeter, with anticipated application for the International Linear Collider. Assembling the modules for such a detector will involve special bonding technologies for the interconnections, especially for attaching a silicon detector wafer to a flex cable readout bus. We review the interconnect technologies involved, including oxidation removal processes, pad surface preparation, solder ball selection and placement, and bond quality assurance. Our results show that solder ball bonding is a promising technique for the Si-W ECAL, and unresolved issues are being addressed.