Source author record

B. N. V. Edwards

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

2works
3topics
4close collaborators

Published work

2 publications

preprint2021arXiv

The Electric Field Dependence of Single Electron Emission in the PIXeY Two-Phase Xenon Detector

Dual phase xenon detectors are widely used in experimental searches for galactic darkmatter particles. The origin of single electron backgrounds following prompt scintillation and proportional scintillation signals in these detectors is not fully understood, although there has been progress in recent years. In this paper, we describe single electron backgrounds in 83mKr{}^{83m}Kr calibration events and their correlation with drift and extraction fields, using the Particle Identification in Xenon at Yale (PIXeY) dual-phase xenon time projection chamber. The single electron background induced by the Fowler-Nordheim (FN) effect is measured, and its electric field dependence is quantified. The photoionization of grids and impurities by prompt scintillation and proportional scintillation also contributes to the single electron background.

preprint2019arXiv

Analysis of 83m^{83m}Kr Prompt Scintillation Signals in the PIXeY Detector

Prompt scintillation signals from 83m^{83m}Kr calibration sources are a useful metric to calibrate the spatial variation of light collection efficiency and electric field magnitude of a two phase liquid-gas xenon time projection chamber. Because 83m^{83m}Kr decays in two steps, there are two prompt scintillation pulses for each calibration event, denoted S1a and S1b. We study the ratio of S1b to S1a signal sizes in the Particle Identification in Xenon at Yale (PIXeY) experiment and its dependence on the time separation between the two signals (ΔtΔt), notably its increase at low ΔtΔt. In PIXeY data, the ΔtΔt dependence of S1b/S1a is observed to exhibit two exponential components: one with a time constant of 0.05±0.02μs0.05 \pm 0.02μs, which can be attributed to processing effects and pulse overlap and one with a time constant of 10.2±2.2μs10.2 \pm 2.2μs that increases in amplitude with electric drift field, the origin of which is not yet understood.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.