Researcher profile

Ayut Limphirat

Ayut Limphirat contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
11works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

11 published item(s)

preprint2022arXiv

Correcting the $B_A$ coalescence factor at GSI-HADES and RHIC-BES energies

We investigate the coalescence factors $B_2$ and $B_3$ at low collision energies ($\sqrt{s_\mathrm{NN}}<6$ GeV) with special focus on the HADES and RHIC-BES experiments. It is shown that, in order to properly interpret the coalescence factors $B_A$, two important corrections are necessary: I) $B_2$ has to be calculated using the proton $\times$ neutron yields in the denominator, instead of the square of the proton yield, and II) the primordial proton (neutron) densities have to be used for the normalization and not the final state (free) protons (neutrons). Both effects lead to a drastic reduction of $B_2$ and $B_3$ at low energies. This reduction decreases the discrepancy between the volumes extracted from HBT measurements and the volumes extracted from the coalescence factor ($V\propto 1/B_2$). While at HADES and low RHIC-BES energies these corrections are substantial, they become irrelevant above $\sqrt{s_\mathrm{NN}}>6$ GeV. The proposed correction method is model independent and is only based on the measurement of protons, clusters and charged pions.

preprint2022arXiv

Cumulants of the chiral order parameter at lower RHIC energies

We study cumulants of the chiral order parameter as function of beam energy as a possible signal for the presence of a critical end point and first-order phase transition in the QCD phase diagram. We model the expansion of a heavy-ion collision by a fluid dynamic expansion coupled to the explicit propagation of the chiral order parameter sigma via a Langevin equation. We evolve the medium until a parametrized freeze-out condition is met where we calculate event-by-event fluctuations and cumulants of sigma which are expected to follow the trend of net-proton number cumulants. We emphasize the role of a nonequilibrium first-order phase transition: The presence of an unstable phase causes the well-known bending of the trajectories in the space of temperature and baryochemical potential. For these cases at lower beam energies, the system crosses the freeze-out line more than once, allowing us to calculate a range of cumulants for each initial condition which are overall enhanced for the second hit of the freeze-out line. We thus find not only the critical end point but also the phase transition of the underlying model clearly reflected in the cumulants. The impact of volume fluctuations is demonstrated to play a measurable role for fluid dynamical evolutions that last significantly long.

preprint2022arXiv

Mass Testing and Characterization of 20-inch PMTs for JUNO

Main goal of the JUNO experiment is to determine the neutrino mass ordering using a 20kt liquid-scintillator detector. Its key feature is an excellent energy resolution of at least 3 % at 1 MeV, for which its instruments need to meet a certain quality and thus have to be fully characterized. More than 20,000 20-inch PMTs have been received and assessed by JUNO after a detailed testing program which began in 2017 and elapsed for about four years. Based on this mass characterization and a set of specific requirements, a good quality of all accepted PMTs could be ascertained. This paper presents the performed testing procedure with the designed testing systems as well as the statistical characteristics of all 20-inch PMTs intended to be used in the JUNO experiment, covering more than fifteen performance parameters including the photocathode uniformity. This constitutes the largest sample of 20-inch PMTs ever produced and studied in detail to date, i.e. 15,000 of the newly developed 20-inch MCP-PMTs from Northern Night Vision Technology Co. (NNVT) and 5,000 of dynode PMTs from Hamamatsu Photonics K. K.(HPK).

preprint2022arXiv

Net-proton number cumulant ratios as function of beam energy from an expanding nonequilibrium chiral fluid

The beam energy scan program at RHIC provides data on net-proton number fluctuations with the goal to detect the QCD critical end point and first-order phase transition. Interpreting these experimental signals requires a vital understanding of the interplay of critical phenomena and the nonequilibrium dynamics of the rapidly expanding fireball. We study these aspects with a fluid dynamic expansion coupled to the explicit propagation of the chiral order parameter sigma via a Langevin equation. Assuming a sigma-proton coupling through an effective proton mass, we relate cumulants of the order parameter and the net-proton number at freeze-out and obtain observable cumulant ratios as a function of beam energy. We emphasize the role of the nonequilibrium first-order phase transition where a mixed phase with gradual freeze-out can significantly alter the cumulants. We find that the presence of a critical end point is clearly visible in the cumulant ratios for a relatively wide range of center-of-mass energies.

preprint2021arXiv

$P_c$ Resonances in the Compact Pentaquark Picture

$P_c$ resonances are studied in the approach of quark model and group theory. It is found that there are totally 17 possible pentaquark states with the quark contents $q^3Q \bar Q$ ($q$ are $u$ and $d$ quarks; $Q$ is $c$ quark) in the compact pentaquark picture, where the hidden heavy pentaquark states may take the color singlet-singlet ($[111]_{qqq}\otimes [111]_{c \bar c}$) and color octet-octet ($[21]_{qqq}\otimes [21]_{c \bar c}$) configurations. The partial decay widths of hidden heavy pentaquark states are calculated for all possible decay channels. The results show that the $pJ/ψ$ is the dominant decay channel for both the spin $3/2$ and $1/2$ pentaquark states, and indicate that the $P_c(4440)$ may not be a compact pentaquark state while $P_c(4312)$ and $P_c(4457)$ could be the spin-$\frac{1}{2}$ and spin-$\frac{3}{2}$ pentaquark states, respectively.

preprint2021arXiv

JUNO Physics and Detector

The Jiangmen Underground Neutrino Observatory (JUNO) is a 20 kton LS detector at 700-m underground. An excellent energy resolution and a large fiducial volume offer exciting opportunities for addressing many important topics in neutrino and astro-particle physics. With 6 years of data, the neutrino mass ordering can be determined at 3-4 sigma and three oscillation parameters can be measured to a precision of 0.6% or better by detecting reactor antineutrinos. With 10 years of data, DSNB could be observed at 3-sigma; a lower limit of the proton lifetime of 8.34e33 years (90% C.L.) can be set by searching for p->nu_bar K^+; detection of solar neutrinos would shed new light on the solar metallicity problem and examine the vacuum-matter transition region. A core-collapse supernova at 10 kpc would lead to ~5000 IBD and ~2000 (300) all-flavor neutrino-proton (electron) scattering events. Geo-neutrinos can be detected with a rate of ~400 events/year. We also summarize the final design of the JUNO detector and the key R&D achievements. All 20-inch PMTs have been tested. The average photon detection efficiency is 28.9% for the 15,000 MCP PMTs and 28.1% for the 5,000 dynode PMTs, higher than the JUNO requirement of 27%. Together with the >20 m attenuation length of LS, we expect a yield of 1345 p.e. per MeV and an effective energy resolution of 3.02%/\sqrt{E (MeV)}$ in simulations. The underwater electronics is designed to have a loss rate <0.5% in 6 years. With degassing membranes and a micro-bubble system, the radon concentration in the 35-kton water pool could be lowered to <10 mBq/m^3. Acrylic panels of radiopurity <0.5 ppt U/Th are produced. The 20-kton LS will be purified onsite. Singles in the fiducial volume can be controlled to ~10 Hz. The JUNO experiment also features a double calorimeter system with 25,600 3-inch PMTs, a LS testing facility OSIRIS, and a near detector TAO.

preprint2020arXiv

Feasibility and physics potential of detecting $^8$B solar neutrinos at JUNO

The Jiangmen Underground Neutrino Observatory~(JUNO) features a 20~kt multi-purpose underground liquid scintillator sphere as its main detector. Some of JUNO&#39;s features make it an excellent experiment for $^8$B solar neutrino measurements, such as its low-energy threshold, its high energy resolution compared to water Cherenkov detectors, and its much large target mass compared to previous liquid scintillator detectors. In this paper we present a comprehensive assessment of JUNO&#39;s potential for detecting $^8$B solar neutrinos via the neutrino-electron elastic scattering process. A reduced 2~MeV threshold on the recoil electron energy is found to be achievable assuming the intrinsic radioactive background $^{238}$U and $^{232}$Th in the liquid scintillator can be controlled to 10$^{-17}$~g/g. With ten years of data taking, about 60,000 signal and 30,000 background events are expected. This large sample will enable an examination of the distortion of the recoil electron spectrum that is dominated by the neutrino flavor transformation in the dense solar matter, which will shed new light on the tension between the measured electron spectra and the predictions of the standard three-flavor neutrino oscillation framework. If $Δm^{2}_{21}=4.8\times10^{-5}~(7.5\times10^{-5})$~eV$^{2}$, JUNO can provide evidence of neutrino oscillation in the Earth at the about 3$σ$~(2$σ$) level by measuring the non-zero signal rate variation with respect to the solar zenith angle. Moveover, JUNO can simultaneously measure $Δm^2_{21}$ using $^8$B solar neutrinos to a precision of 20\% or better depending on the central value and to sub-percent precision using reactor antineutrinos. A comparison of these two measurements from the same detector will help elucidate the current tension between the value of $Δm^2_{21}$ reported by solar neutrino experiments and the KamLAND experiment.

preprint2020arXiv

Influence of centrality definition and detector efficiency on the net-proton kurtosis

We study the influence of the centrality definition and detector efficiency on the net-proton kurtosis for minimum bias Au+Au collisions at a beam energy of $\sqrt{s_{\mathrm{NN}}}= 7.7$ GeV by using the UrQMD model. We find that different ways of defining the centrality lead to different cumulant ratios. Moreover, we demonstrate that the kurtosis is suppressed for central collisions when a wider transverse momentum acceptance is used. Finally, the influence of a detector efficiency on the measured cumulant ratios is estimated.

preprint2020arXiv

Pentaquark components in low-lying baryon resonances

We study pentaquark states of both light $q^4\bar q$ and hidden heavy $q^3 Q\bar Q$ (q = u,d,s quark in SU(3) flavor symmetry; Q = c, b quark) systems with a general group theory approach in the constituent quark model, and the spectrum of light baryon resonances in the ansatz that the $l=1$ baryon states may consist of the $q^3$ as well as $q^4\bar q$ pentaquark component. The model is fitted to ground state baryons and light baryon resonances which are believed to be normal three-quark states. The work reveals that the $N(1535)1/2^{-}$ and $N(1520)3/2^-$ may consist of a large $q^4\bar q$ component while the $N(1895)1/2^{-}$ and $N(1875)3/2^-$ are respectively their partners, and the $N^+(1685)$ might be a $q^4\bar q$ state. By the way, a new set of color-spin-flavor-spatial wave function for $q^3 Q\bar Q$ systems in the compact pentaquark picture are constructed systematically for studying hidden charm pentaquark states.

preprint2020arXiv

TAO Conceptual Design Report: A Precision Measurement of the Reactor Antineutrino Spectrum with Sub-percent Energy Resolution

The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future reactor neutrino experiments, and to provide a benchmark measurement to test nuclear databases. A spherical acrylic vessel containing 2.8 ton gadolinium-doped liquid scintillator will be viewed by 10 m^2 Silicon Photomultipliers (SiPMs) of >50% photon detection efficiency with almost full coverage. The photoelectron yield is about 4500 per MeV, an order higher than any existing large-scale liquid scintillator detectors. The detector operates at -50 degree C to lower the dark noise of SiPMs to an acceptable level. The detector will measure about 2000 reactor antineutrinos per day, and is designed to be well shielded from cosmogenic backgrounds and ambient radioactivities to have about 10% background-to-signal ratio. The experiment is expected to start operation in 2022.

preprint2019arXiv

First, second, third and fourth flow harmonics of deuterons and protons in Au+Au reactions at 1.23 A GeV

We explore the directed, elliptic, triangular and quadrangular flow of deuterons in Au+Au reactions at a beam energy of 1.23 AGeV within the UrQMD approach. These investigations are of direct relevance for the HADES experiment at GSI that has recently presented first data on the flow of light clusters in Au+Au collisions at 1.23 AGeV. To address the deuteron flow, UrQMD has been extended to include deuteron formation by coalescence. We find that this ansatz provides a very good description of the measured deuteron flow data, if a hard equation of state is used for the simulation. In addition we show that light cluster formation has a sizable impact on the proton flow and has to be taken into account to obtain reliable results in the forward/backward region. Based on the observed scaling of the flow, which is a natural result of coalescence, we conclude that deuteron production at GSI energies is a final state recombination effect. Finally, we also discuss the scaling relations of the higher order flow components up to $v_4$. We show that $v_3 \sim v_1v_2$ and $v_4 \sim v_2^2$ as function of transverse momentum and that the integrated $v_2^2 \sim v_4$ over the investigated energy range from $E_{lab}$=0.1 AGeV to 40 AGeV.