Researcher profile

Arpan Koirala

Arpan Koirala contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2023arXiv

Consensus based phase connectivity identification for distribution network with limited observability

The mitigation of distribution network (DN) unbalance and the use of single-phase flexibility for congestion mitigation requires accurate phase connection information, which is often not available. For a large DN, the naive phase identification proposed in the majority of the prior works using a single voltage reference does not scale well for a multi-feeder DN. We present a consensus algorithm-based phase identification mechanism which uses multiple three-phase reference points to improve the prediction of phases. Due to the absence of real measurements for a real-suburban German DN, the algorithms are developed and evaluated over synthetic data using a digital twin. To utilize strongly correlated measurements, the DN is clustered into zones. We observe those reference measurements located in the same zone as the single-phase consumer leads to accurate prediction of DN phases. Four consensus algorithms are developed and compared. Using numerical results, we recommend the most robust phase identification mechanism. In our evaluation, measurement error, and the impact of the neutral conductor are also assessed. We assume limited DN observability and apply our findings to a German DN without smart meters, but only less than 8% of nodes have measurement boxes along with single-phase consumers with a home energy management system. Voltage time series for 1 month (hourly sampled) is utilized. The numerical results indicate that for 1% accuracy class measurement, the phase connectivity of 308 out of 313 single-phase consumers in a German DN can be identified. Further, we also propose metrics quantifying the goodness of the phase identification. The phase identification framework based on consensus algorithms for DN zones is scalable for large DN and robust towards measurement errors as the estimation is not dependent on a single measurement point.

preprint2022arXiv

Chance constrained day-ahead robust flexibility needs assessment for low voltage distribution network

For market-based procurement of low voltage (LV) flexibility, DSOs identify the amount of flexibility needed for resolving probable distribution network (DN) voltage and thermal congestion. A framework is required to avoid over or under procurement of flexibility in the presence of uncertainty. To this end, we propose a scenario-based robust chance-constrained (CC) day-ahead flexibility needs assessment (FNA) framework. The CC level is analogous to the risk DSO is willing to take in flexibility planning. Multi-period optimal power flow is performed to calculate the amount of flexibility needed to avoid network issues. Flexibility is defined in terms of nodal power ramp-up and ramp-down and cumulative energy needs over a full day for each node. Future uncertainties are considered as multiple scenarios generated using multivariate Gaussian distribution and Cholesky decomposition. These scenarios are utilized to solve the flexibility needs assessment optimal power flow (FNA-OPF) problem. Zonal clustering of an LV feeder is performed using electrical distance as a measure and spatial partitioning. The FNA tool calculates ramp-up and ramp-down flexibility's power and energy requirements. Energy and power needs are often valued differently in many energy markets. We identify the marginal value of flexibility associated with energy and power needs separately. From numerical results for an LV feeder, it is observed that zonal flexibility needs assessment is more immune to uncertainty than nodal flexibility needs, making it more useful for DSOs to evaluate day-ahead flexibility procurement. We also propose a Pareto optimal mechanism for selecting CC level to reduce flexibility needs while reducing DN congestion.

preprint2022arXiv

Flexible and curtailable resource activation in three-phase unbalanced distribution networks

The need for flexibility and curtailable resources is crucial for ensuring the healthy operation of future distribution networks (DN). In this work, we propose a network-state driven framework that distribution system operators (DSOs) can utilize for activating flexible and curtailable resources for alleviating network voltage and thermal issues, while accounting for network voltage and current imbalances. This approach assumes the availability of dynamic network state information and uses nodal sensitivities for calculating a flexibility activation signal (FAS). The signal design is motivated by volt-Var and volt-watt inverter control, and thus bounded. The FAS also considers network voltage and current imbalances and incentivizes activation of active and reactive power flexibilities for reducing imbalance in addition to mitigating voltage and thermal imbalances in a three-phase unbalanced distribution network. The FAS design resembles optimal power flow duals, often used as locational marginal prices. The gains associated with the imbalance component of the objective function of three-phase unbalanced resource activation (TPU-RA) is performed using Pareto optimality. A numerical case study is presented showing the efficacy of the proposed framework in avoiding network issues while reducing voltage unbalance factor by more than 80\%. Further, DN's flexibility needs are quantified for location and time of day.

preprint2022arXiv

Low Voltage Customer Phase Identification Methods Based on Smart Meter Data

The increased deployment of distributed energy generation and the integration of new, large electric loads such as electric vehicles and heat pumps challenge the correct and reliable operation of low voltage distribution systems. To tackle potential problems, active management solutions are proposed in the literature, which require distribution system models that include the phase connectivity of all the consumers in the network. However, information on the phase connectivity is in practice often unavailable. In this work, several voltage and power measurement-based phase identification methods from the literature are implemented. A consistent comparison of the methods is made across different smart meter accuracy classes and smart meter penetration levels using publicly available data. Furthermore, a novel method is proposed that makes use of ensemble learning and that can combine data from different measurement campaigns. The results indicate that generally better results are obtained with voltage data compared to power data from smart meters of the same accuracy class. If power data is available too, the novel ensemble method can improve the accuracy of the phase identification obtained from voltage data alone.