Source author record

Arnd Doerfler

Arnd Doerfler appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

A novel use of time separation technique to improve flat detector CT perfusion imaging in stroke patients

CT perfusion imaging (CTP) is used in the diagnostic workup of acute ischemic stroke (AIS). CTP may be performed within the angio suite using flat detector CT (FDCT) to help reduce patient management time. In order to significantly improve FDCT perfusion (FDCTP) imaging, data-processing algorithms need to be able to compensate for the higher levels of noise, slow rotation speed, and a lower frame rate of current FDCT devices. We performed a realistic simulation of FDCTP acquisition based on CTP data from seven subjects. We used the time separation technique (TST) as a model-based approach for FDCTP data processing. We propose a novel dimension reduction in which we approximate the time attenuation curves by a linear combination of trigonometric functions. Our goal was to show that the TST can be used even without prior assumptions on the shape of the attenuation profiles. We first demonstrated that a trigonometric basis is suitable for dimension reduction of perfusion data. Using simulated FDCTP data, we have shown that a trigonometric basis in the TST provided better results than the classical straightforward processing even with additional noise. Average correlation coefficients of perfusion maps were improved for cerebral blood flow (CBF), cerebral blood volume, mean transit time (MTT) maps. In a moderate noise scenario, the average Pearson's coefficient for the CBF map was improved using the TST from 0.76 to 0.81. For the MTT map, it was improved from 0.37 to 0.45. Furthermore, we achieved a total processing time from the reconstruction of FDCTP data to the generation of perfusion maps of under 5 min. In our study cohort, perfusion maps created from FDCTP data using the TST with a trigonometric basis showed equivalent perfusion deficits to classic CT perfusion maps. It follows, that this novel FDCTP technique has potential to provide fast and accurate FDCTP imaging for AIS patients.

preprint2020arXiv

Contrast-to-noise ratio analysis of microscopic diffusion anisotropy indices in q-space trajectory imaging

Diffusion anisotropy in diffusion tensor imaging (DTI) is commonly quantified with normalized diffusion anisotropy indices (DAIs). Most often, the fractional anisotropy (FA) is used, but several alternative DAIs have been introduced in attempts to maximize the contrast-to-noise ratio (CNR) in diffusion anisotropy maps. Examples include the scaled relative anisotropy (sRA), the gamma variate anisotropy index (GV), the surface anisotropy (UAsurf), and the lattice index (LI). With the advent of multidimensional diffusion encoding it became possible to determine the presence of microscopic diffusion anisotropy in a voxel, which is theoretically independent of orientation coherence. In accordance with DTI, the microscopic anisotropy is typically quantified by the microscopic fractional anisotropy (uFA). In this work, in addition to the uFA, the four microscopic diffusion anisotropy indices (uDAIs) usRA, uGV, uUAsurf, and uLI are defined in analogy to the respective DAIs by means of the average diffusion tensor and the covariance tensor. Simulations with three representative distributions of microscopic diffusion tensors revealed distinct CNR differences when differentiating between isotropic and microscopically anisotropic diffusion. q-Space trajectory imaging (QTI) was employed to acquire brain in-vivo maps of all indices. For this purpose, a 15 min protocol featuring linear, planar, and spherical tensor encoding was used. The resulting maps were of good quality and exhibited different contrasts, e.g. between gray and white matter. This indicates that it may be beneficial to use more than one uDAI in future investigational studies.