Source author record

Antoine Delon

Antoine Delon appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

Combining fluorescence fluctuations and photobleaching to quantify surface density

We establish a method, called pbFFS for photobleaching Fluctuation Fluorescence Spectroscopy, which aims at characterizing molecules or particles labelled with a unknown distribution or fluorophores. Using photobleaching as a control parameter, pbFFS provides information on the distribution of labels and a more reliable estimation of the absolute density or concentration of these molecules. We present a complete theoretical derivation of the pbFFS approach and experimentally apply it to measure the surface density of a monolayer of fluorescently tagged streptavidin molecules that can be used as a base platform for biomimetic systems. The surface density measured by pbFFS is consistent with the results of more standard surface techniques, such as ellipsometry. Compared to those techniques, pbFFS has two main advantages: it enables in situ characterization (no dedicated substrates are required) and is applicable to low masses of adsorbed molecules, as demonstrated here by quantifying the density of biotin-Atto molecules that bind to the streptavidin layer. Besides molecules immobilized on surfaces, we also applied pbFFS to molecules diffusing in solution, to confirm the distribution of labels found on surfaces. Hence, pbFFS provides a set of tools to investigate molecules attached to a variable number of fluorophores, with the aim toquantify either the number of molecules or the distribution of fluorophores, the latter case being especially relevant for oligomerization studies.

preprint2022arXiv

Optimal transfer functions for bandwidth-limited imaging

One of the fundamental limits of classical optical microscopy is the diffraction limit of optical resolution. It results from the finite bandwidth of the optical transfer function (or OTF) of an optical microscope, which restricts the maximum spatial frequencies that are transmitted by a microscope. However, given the frequency support of the OTF, which is fully determined by the used optical hardware, an open and unsolved question is what is the optimal amplitude and phase distribution of spatial frequencies across this support that delivers the "sharpest" possible image. In this paper, we will answer this question and present a general rule how to find the optimal OTF for any given imaging system. We discuss our result in the context of optical microscopy, by considering in particular the cases of wide-field microscopy, confocal Image Scanning Microscopy (ISM), 4pi microscopy, and Structured Illumination Microscopy (SIM). Our results are important for finding optimal deconvolution algorithms for microscopy images, and we demonstrate this experimentally on the example of ISM. Our results can also serve as a guideline for designing optical systems that deliver best possible images, and they can be easily generalized to non-optical imaging such as telescopic imaging, ultrasound imaging, or magnetic resonance imaging.

preprint2014arXiv

Correction of cell-induced optical aberrations in a fluorescence fluctuation microscope

We describe the effect of optical aberrations on fluorescence fluctuations microscopy (FFM), when focusing through a single living cell. FFM measurements are performed in an aqueous fluorescent solution and prove to be a highly sensitive tool to assess the optical aberrations introduced by the cell. We demonstrate an adaptive optics (AO) system to remove the aberration-related bias in the FFM measurements. Our data show that AO is not only useful when imaging deep in tissues but also when performing FFM measurements through a single cellular layer. This work paves the way for the application of FFM to complex three-dimensional multicellular samples.

preprint2011arXiv

Adaptive Optics for Fluorescence Correlation Spectroscopy

Fluorescence Correlation Spectroscopy (FCS) yields measurement parameters (number of molecules, diffusion time) that characterize the concentration and kinetics of fluorescent molecules within a supposedly known observation volume. Absolute derivation of concentrations and diffusion constants therefore requires preliminary calibrations of the confocal Point Spread Function with phantom solutions under perfectly controlled environmental conditions. In this paper, we quantify the influence of optical aberrations on single photon FCS and demonstrate a simple Adaptive Optics system for aberration correction. Optical aberrations are gradually introduced by focussing the excitation laser beam at increasing depths in fluorescent solutions with various refractive indices, which leads to drastic depth-dependent bias in the estimated FCS parameters. Aberration correction with a Deformable Mirror stabilizes these parameters within a range of several tens of \mum into the solution. We also demonstrate, both theoretically and experimentally, that the molecular brightness scales as the Strehl ratio squared.

preprint2011arXiv

Multi-confocal Fluorescence Correlation Spectroscopy : experimental demonstration and potential applications for living cell measurements

We report, for the first time, a multi-confocal Fluorescence Correlation Spectroscopy (mFCS) technique which allows parallel measurements at different locations, by combining a Spatial Light Modulator (SLM), with an Electron Multiplying-CCD camera (EM-CCD). The SLM is used to produce a series of laser spots, while the pixels of the EM-CCD play the roles of virtual pinholes. The phase map addressed to the SLM is calculated by using the spherical wave approximation and makes it possible to produce several diffraction limited laser spots, either aligned or spread over the field of view. To attain fast enough imaging rates, the camera has been used in different acquisition modes, the fastest of which leads to a time resolution of 100 $μ$s. We qualified the experimental set-up by using solutions of sulforhodamine G in glycerol and demonstrated that the observation volumes are similar to that of a standard confocal set-up. To demonstrate that our mFCS method is suitable for intracellular studies, experiments have been conducted on two stable cell lines: mouse embryonic fibroblasts expressing eGFP-actin and H1299 cells expressing the heat shock factor fusion protein HSF1-eGFP. In the first case we could recover, by analyzing the auto-correlation curves, the diffusion constant of G-actin within the cytoplasm, although we were also sensitive to the complex network of interactions with F-actin. Concerning HSF1, we could clearly observe the modifications of the number of molecules and of the HSF1 dynamics during heat shock.

preprint2010arXiv

Measuring, in solution, multiple-fluorophore labeling by combining Fluorescence Correlation Spectroscopy and photobleaching

Determining the number of fluorescent entities that are coupled to a given molecule (DNA, protein, etc.) is a key point of numerous biological studies, especially those based on a single molecule approach. Reliable methods are important, in this context, not only to characterize the labeling process, but also to quantify interactions, for instance within molecular complexes. We combined Fluorescence Correlation Spectroscopy (FCS) and photobleaching experiments to measure the effective number of molecules and the molecular brightness as a function of the total fluorescence count rate on solutions of cDNA (containing a few percent of C bases labeled with Alexa Fluor 647). Here, photobleaching is used as a control parameter to vary the experimental outputs (brightness and number of molecules). Assuming a Poissonian distribution of the number of fluorescent labels per cDNA, the FCS-photobleaching data could be easily fit to yield the mean number of fluorescent labels per cDNA strand (@ 2). This number could not be determined solely on the basis of the cDNA brightness, because of both the statistical distribution of the number of fluorescent labels and their unknown brightness when incorporated in cDNA. The statistical distribution of the number of fluorophores labeling cDNA was confirmed by analyzing the photon count distribution (with the cumulant method), which showed clearly that the brightness of cDNA strands varies from one molecule to the other.