Source author record

Andrew Klose

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

3works
3topics
4close collaborators

Published work

3 publications

preprint2022arXiv

Ground State Magnetic Dipole Moment of 40^{40}Sc

The hyperfine coupling constants of the proton dripline odd-odd 40^{40}Sc nucleus were deduced from the hyperfine spectrum of the 3d4s 3D23d4s\,^3\text{D}_2\,↔\leftrightarrow\,3d4p 3F3∘3d4p\,^3\text{F}^\circ_3 transition in Sc II, measured by the bunched beam collinear laser spectroscopy technique. The ground state magnetic dipole and electric quadrupole moments were determined for the first time as μμ\,=\,+5.57(4)(2) μN+5.57(4)(2)\,μ_N and QQ\,=\,+42(38)(28) e2  fm2+42(38)(28)\,e^2\;{\rm fm^2}, respectively. The magnetic moment is well reproduced by the additivity rule with magnetic moments of neighboring odd-even nuclei in the vicinity of the doubly-magic 40^{40}Ca nucleus. An ab-initio multishell valence-space Hamiltonian was also employed to calculate the magnetic moment of 40^{40}Sc, which spans across the sdsd and fpfp nuclear shells, where we obtained good agreements.

preprint2016arXiv

Rapid, broadband spectroscopic temperature measurement of CO2 using VIPA spectroscopy

Time-resolved spectroscopic temperature measurements of a sealed carbon dioxide sample cell were realized with an optical frequency comb combined with a two-dimensional dispersive spectrometer. A supercontinuum laser source based on an erbium fiber mode-locked laser was employed to generate coherent light around 2000 nm (5000 cm-1). The laser was passed through a 12-cm long cell containing CO2, and the transmitted light was analyzed in a virtually imaged phased array- (VIPA-) based spectrometer. Broadband spectra spanning more than 100 cm-1 with a spectral resolution of roughly 0.075 cm-1 (2.2 GHz) were acquired with an integration period of 2 ms. The temperature of the CO2 sample was deduced from fitting a modeled spectrum to the line intensities of the experimentally acquired spectrum. Temperature dynamics on the time scale of milliseconds were observed with a temperature resolution of 2.6 K. The spectroscopically-deduced temperatures agreed with temperatures of the sample cell measured with a thermistor. Potential applications of this technique include quantitative measurement of carbon dioxide concentration and temperature dynamics in gas-phase chemical reactions (e.g., combustion), and plasma diagnostics.

preprint2015arXiv

Mid-Infrared Optical Frequency Combs based on Difference Frequency Generation for Molecular Spectroscopy

Mid-infrared femtosecond optical frequency combs were produced by difference frequency generation of the spectral components of a near-infrared comb in a 3-mm-long MgO:PPLN crystal. We observe strong pump depletion and 9.3 dB parametric gain in the 1.5 μm signal, which yields powers above 500 mW (3 μW/mode) in the idler with spectra covering 2.8 μm to 3.5 μm. Potential for broadband, high-resolution molecular spectroscopy is demonstrated by absorption spectra and interferograms obtained by heterodyning two combs.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.