Source author record

Andrea Giuliani

Andrea Giuliani appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2025arXiv

Characterization of mini-CryoCube detectors from the Ricochet experiment commissioning at the Institut Laue-Langevin

The Ricochet experiment aims to measure the coherent elastic neutrino-nucleus scattering process from antineutrinos emitted by a research nuclear reactor operated by the Institut Laue-Langevin (Grenoble, France). This article presents a description of the Ricochet experimental installation and the detector performance achieved during its commissioning with a mini-CryoCube module consisting of three 42-gram germanium cryogenic calorimeters. The baseline resolutions and background levels are reported both during reactor-on and reactor-off periods, and as noise mitigation techniques were improved. A baseline resolution of 40 eV electron equivalent was achieved for the ionization channel after setup improvements, and the phonon channel resolutions ranged from 50 to 80 eV of total phonon energy. In the energy region from 2 to 7 keV, a nuclear recoil rate of 15(2) events/(kg day keV) is measured during the reactor-off period selecting events in coincidence with muon veto signals. This rate is in agreement with the cosmogenic neutron rate calculated from GEANT4 simulations. After the rejection of events in coincidence with signals in the muon veto detectors, a combined 90% C.L. limit on the nuclear recoil background of < 9 events/(kg day keV) is obtained in that energy region during the reactor-on period, which is compatible with our GEANT4 model calculation corresponding to a total rate of 5 events/(kg day keV). The sensitivity of this analysis was however found to be limited by a surface event contamination which is currently being addressed by the Ricochet Collaboration with upgraded detectors.

preprint2013arXiv

A search for lines in the bright X-ray afterglow of GRB120711A

GRB120711A, discovered and rapidly localized by the INTEGRAL satellite, attracted particular interest due to its high gamma-ray fluence, very bright X-ray afterglow, and the detection of a prompt optical transient and of long-lasting emission at GeV energies. A follow-up observation carried out with the XMM-Newton satellite has provided an X-ray spectrum in the 0.3-10 keV with unprecedented statistics for a GRB afterglow 20 hours after the burst. The spectrum is well fit by a power-law with photon index 1.87+-0.01, modified by absorption in our Galaxy and in the GRB host at z=1.4. A Galactic absorption consistent with that estimated from neutral hydrogen observations is obtained only with host metallicity lower than 0.05 of the Solar value. We report the results of a sensitive search for emission and absorption lines using the matched filter smoothing method (Rutledge and Sako 2003). No statistically significant lines were found. The upper limits on the equivalent width of emission lines, derived through Monte Carlo simulations, are few tens of eV, a factor about 10 lower than that of the possible lines reported in the literature for other bursts.

preprint2011arXiv

Composite macro-bolometers for the rejection of surface radioactive background in rare-event experiments

Experiments searching for rare events, such as neutrinoless double beta decay and interactions of dark matter candidates, require extremely low levels of background. When these experiments are performed using macro-bolometers, radioactive contamination near the surfaces is of particular concern. In order to control the effects of surface contamination, we developed a novel technique that uses composite macro-bolometers to identify energy depositions that occur close to the surfaces of materials immediately surrounding the detector. The composite macro-bolometer proposed and studied here consists of a main energy absorber that is thermally coupled to and entirely surrounded by thin absorbers that act as active shields. Surface energy depositions can be rejected by the analysis of simultaneous signals in the main absorber and the shields. In this paper, we describe a full thermal model and experimental results for three prototype detectors. The detectors consist of Ge, Si, or TeO2 thin absorbers as active shields, all with TeO2 crystals as main absorbers. In all cases, the surface event rejection capability is clearly demonstrated. In addition, simulations and preliminary results show that it is possible to detect energy depositions that occurred on the shields without separate readout channels for them. The energy depositions in the shields are distinguished from those in the main absorber through pulse shape discrimination. This simplification makes this technique a viable method for the rejection of surface energy depositions in next-generation bolometric double beta decay searches, such as possible extensions or upgrades of the CUORE experiment.