Source author record

Andras Hajdu

Andras Hajdu appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
8topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2020arXiv

A stochastic approach to handle knapsack problems in the creation of ensembles

Ensemble-based methods are highly popular approaches that increase the accuracy of a decision by aggregating the opinions of individual voters. The common point is to maximize accuracy; however, a natural limitation occurs if incremental costs are also assigned to the individual voters. Consequently, we investigate creating ensembles under an additional constraint on the total cost of the members. This task can be formulated as a knapsack problem, where the energy is the ensemble accuracy formed by some aggregation rules. However, the generally applied aggregation rules lead to a nonseparable energy function, which takes the common solution tools -- such as dynamic programming -- out of action. We introduce a novel stochastic approach that considers the energy as the joint probability function of the member accuracies. This type of knowledge can be efficiently incorporated in a stochastic search process as a stopping rule, since we have the information on the expected accuracy or, alternatively, the probability of finding more accurate ensembles. Experimental analyses of the created ensembles of pattern classifiers and object detectors confirm the efficiency of our approach. Moreover, we propose a novel stochastic search strategy that better fits the energy, compared with general approaches such as simulated annealing.

preprint2014arXiv

A Two-phase Decision Support Framework for the Automatic Screening of Digital Fundus Images

In this paper we give a brief review on the present status of automated detection systems describe for the screening of diabetic retinopathy. We further detail an enhanced detection procedure that consists of two steps. First, a pre-screening algorithm is considered to classify the input digital fundus images based on the severity of abnormalities. If an image is found to be seriously abnormal, it will not be analysed further with robust lesion detector algorithms. As a further improvement, we introduce a novel feature extraction approach based on clinical observations. The second step of the proposed method detects regions of interest with possible lesions on the images that previously passed the pre-screening step. These regions will serve as input to the specific lesion detectors for detailed analysis. This procedure can increase the computational performance of a screening system. Experimental results show that both two steps of the proposed approach are capable to efficiently exclude a large amount of data from further processing, thus, to decrease the computational burden of the automatic screening system.

preprint2014arXiv

An ensemble-based system for automatic screening of diabetic retinopathy

In this paper, an ensemble-based method for the screening of diabetic retinopathy (DR) is proposed. This approach is based on features extracted from the output of several retinal image processing algorithms, such as image-level (quality assessment, pre-screening, AM/FM), lesion-specific (microaneurysms, exudates) and anatomical (macula, optic disc) components. The actual decision about the presence of the disease is then made by an ensemble of machine learning classifiers. We have tested our approach on the publicly available Messidor database, where 90% sensitivity, 91% specificity and 90% accuracy and 0.989 AUC are achieved in a disease/no-disease setting. These results are highly competitive in this field and suggest that retinal image processing is a valid approach for automatic DR screening.

preprint2014arXiv

An Ensemble-based System for Microaneurysm Detection and Diabetic Retinopathy Grading

Reliable microaneurysm detection in digital fundus images is still an open issue in medical image processing. We propose an ensemble-based framework to improve microaneurysm detection. Unlike the well-known approach of considering the output of multiple classifiers, we propose a combination of internal components of microaneurysm detectors, namely preprocessing methods and candidate extractors. We have evaluated our approach for microaneurysm detection in an online competition, where this algorithm is currently ranked as first and also on two other databases. Since microaneurysm detection is decisive in diabetic retinopathy grading, we also tested the proposed method for this task on the publicly available Messidor database, where a promising AUC 0.90 with 0.01 uncertainty is achieved in a 'DR/non-DR'-type classification based on the presence or absence of the microaneurysms.

preprint2014arXiv

An Unsupervised Ensemble-based Markov Random Field Approach to Microscope Cell Image Segmentation

In this paper, we propose an approach to the unsupervised segmentation of images using Markov Random Field. The proposed approach is based on the idea of Bit Plane Slicing. We use the planes as initial labellings for an ensemble of segmentations. With pixelwise voting, a robust segmentation approach can be achieved, which we demonstrate on microscope cell images. We tested our approach on a publicly available database, where it proven to be competitive with other methods and manual segmentation.

preprint2012arXiv

Approximations of the Euclidean distance by chamfer distances

Chamfer distances play an important role in the theory of distance transforms. Though the determination of the exact Euclidean distance transform is also a well investigated area, the classical chamfering method based upon "small" neighborhoods still outperforms it e.g. in terms of computation time. In this paper we determine the best possible maximum relative error of chamfer distances under various boundary conditions. In each case some best approximating sequences are explicitly given. Further, because of possible practical interest, we give all best approximating sequences in case of small (i.e. 5 by 5 and 7 by 7) neighborhoods.