Source author record

Anat Bremler-Barr

Anat Bremler-Barr appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Dynamic-Deep: Tune ECG Task Performance and Optimize Compression in IoT Architectures

Monitoring medical data, e.g., Electrocardiogram (ECG) signals, is a common application of Internet of Things (IoT) devices. Compression methods are often applied on the massive amounts of sensor data generated prior to sending it to the Cloud to reduce the storage and delivery costs. A lossy compression provides high compression gain (CG), but may reduce the performance of an ECG application (downstream task) due to information loss. Previous works on ECG monitoring focus either on optimizing the signal reconstruction or the task's performance. Instead, we advocate a self-adapting lossy compression solution that enables configuring a desired performance level on the downstream tasks while maintaining an optimized CG that reduces Cloud costs. We propose Dynamic-Deep, a task-aware compression geared for IoT-Cloud architectures. Our compressor is trained to optimize the CG while maintaining the performance requirement of the downstream tasks chosen out of a wide range. In deployment, the IoT edge device adapts the compression and sends an optimized representation for each data segment, accounting for the downstream task's desired performance without relying on feedback from the Cloud. We conduct an extensive evaluation of our approach on common ECG datasets using two popular ECG applications, which includes heart rate (HR) arrhythmia classification. We demonstrate that Dynamic-Deep can be configured to improve HR classification F1-score in a wide range of requirements. One of which is tuned to improve the F1-score by 3 and increases CG by up to 83% compared to the previous state-of-the-art (autoencoder-based) compressor. Analyzing Dynamic-Deep on the Google Cloud Platform, we observe a 97% reduction in cloud costs compared to a no compression solution.

preprint2010arXiv

On the Dynamics of IP Address Allocation and Availability of End-Hosts

The availability of end-hosts and their assigned routable IP addresses has impact on the ability to fight spammers and attackers, and on peer-to-peer application performance. Previous works study the availability of hosts mostly by using either active pinging or by studying access to a mail service, both approaches suffer from inherent inaccuracies. We take a different approach by measuring the IP addresses periodically reported by a uniquely identified group of the hosts running the DIMES agent. This fresh approach provides a chance to measure the true availability of end-hosts and the dynamics of their assigned routable IP addresses. Using a two month study of 1804 hosts, we find that over 60% of the hosts have a fixed IP address and 90% median availability, while some of the remaining hosts have more than 30 different IPs. For those that have periodically changing IP addresses, we find that the median average period per AS is roughly 24 hours, with a strong relation between the offline time and the probability of altering IP address.