Source author record

Alexej Jerschow

Alexej Jerschow appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2021arXiv

Battery characterization via eddy-current imaging with nitrogen-vacancy centers in diamond

Sensitive and accurate diagnostic technologies with magnetic sensors are of great importance for identifying and localizing defects of rechargeable solid batteries in a noninvasive detection. We demonstrate a microwave-free AC magnetometry method with negatively charged NV centers in diamond based on a cross-relaxation feature between NV centers and individual substitutional nitrogen (P1) centers occurring at 51.2 mT. We apply the technique to non-destructive solid-state battery imaging. By detecting the eddy-current-induced magnetic field of the battery, we distinguish a defect on the external electrode and identify structural anomalies within the battery body. The achieved spatial resolution is $360\,μ\rm m$. The maximum magnetic field and phase shift generated by the battery at the modulation frequency of 5 kHz are estimated as 0.04 mT and 0.03 rad respectively.

preprint2014arXiv

Visualizing Skin Effects in Conductors with MRI: ${}^7$Li MRI Experiments and Calculations

While experiments on metals have been performed since the early days of NMR (and DNP), the use of bulk metal is normally avoided. Instead, often powders have been used in combination with low fields, so that skin depth effects could be neglected. Another complicating factor of acquiring NMR spectra or MRI images of bulk metal is the strong signal dependence on the orientation between the sample and the radio frequency (RF) coil, leading to non-intuitive image distortions and inaccurate quantification. Such factors are particularly important for NMR and MRI of batteries and other electrochemical devices. Here, we show results from a systematic study combining RF field calculations with experimental MRI of $^7$Li metal to visualize skin depth effects directly and to analyze the RF field orientation effect on MRI of bulk metal. It is shown that a certain degree of selectivity can be achieved for particular faces of the metal, simply based on the orientation of the sample. By combining RF field calculations with bulk magnetic susceptibility calculations accurate NMR spectra can be obtained from first principles. Such analyses will become valuable in many applications involving battery systems, but also metals, in general.

preprint2012arXiv

Long Lived NMR Signal in Bone

Solids and rigid tissues such as bone, ligaments, and tendons, typically appear dark in magnetic resonance imaging (MRI), which is due to the extremely short-lived proton nuclear magnetic resonance (NMR) signals. This short lifetime is due to strong dipolar interactions between immobilized proton spins, which render it challenging to detect these signals with sufficient resolution and sensitivity. Here we show the possibility of exciting long-lived signals in cortical bone tissue with a signature consistent with that of bound water signals. Contrary to long-standing belief, it is further shown that dipolar coupling networks are an integral requirement for the excitation of these long-lived signals. The use of these signals could enhance the ability to visualize rigid tissues and solid samples with high sensitivity, resolution, and specificity via MRI.

preprint2012arXiv

Noise and Spin-noise: Cable dependence of Optimal Tuning/Matching Conditions

Previous studies have shown that tuning/matching conditions optimized for transmission and detection can be significantly different for a variety of commercial NMR probes. In addition, it was also shown that by optimizing reception tuning (as opposed to typical transmission or reflection tuning) one may in some cases obtain sensitivity enhancements by as much as 25-50%. In earlier work, spin-noise and absorbed circuit noise signals have also been used to characterize reception optima. In this work, we show how the length of the coaxial transmission line cable between the pre-amplifier and the probe affects the positions of the reception tuning optimum, the radiation damping strength, induced frequency shifts, as well as, the shape of the spin-noise and absorbed circuit noise line shapes.

preprint2011arXiv

Cutoff-Free Traveling Wave NMR

Recently, the concept of traveling-wave NMR/MRI was introduced by Brunner et al. (Nature 457, 994-992 (2009)), who demonstrated MR images acquired using radio frequency (RF) waves propagating down the bore of an MR scanner. One of the significant limitations of this approach is that each bore has a specific cutoff frequency, which can be higher than most Larmor frequencies of at the magnetic field strengths commonly in use for MR imaging and spectroscopy today. We overcome this limitation by using a central conductor in the waveguide and thereby converting it to a transmission line (TL), which has no cutoff frequency. Broadband propagation of waves through the sample thus becomes possible. NMR spectra and images with such an arrangement are presented and genuine traveling wave behavior is demonstrated. In addition to facilitating NMR spectroscopy and imaging in smaller bores via traveling waves, this approach also allows one to perform multinuclear traveling wave experiments (an example of which is shown), and to study otherwise difficult-to-access samples in unusual geometries.