Researcher profile

Alexandra von Meier

Alexandra von Meier contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

Parameter Conditions to Prevent Voltage Oscillations Caused by LTC-Inverter Hunting on Power Distribution Grids

As more distributed energy resources (DERs) are connected to the power grid, it becomes increasingly important to ensure safe and effective coordination between legacy voltage regulation devices and inverter-based DERs. In this work, we show how a distribution circuit model, composed of two LTCs and two inverter devices, can create voltage oscillations even with reasonable choices of control parameters. By modeling the four-device circuit as a switched affine hybrid system, we analyze the system's oscillatory behavior, both during normal operation and after a cyber-physical attack. Through the analysis we determine the specific region of the voltage state space where oscillations are possible and derive conditions on the control parameters to guarantee against the oscillations. Finally, we project the derived parameter conditions onto 2D spaces, and describe the application of our problem formulation to grids with many devices.

preprint2022arXiv

Using Voltage Phasor Control to Avoid Distribution Network Constraint Violations

In this paper, we introduce Voltage Phasor Control (VPC), also known as Phasor Based Control, as a novel way of implementing Optimal Power Flow (OPF). Unlike conventional OPF, in which the power flow optimization broadcasts power injections, the VPC power flow optimization broadcasts voltage phasor setpoints to feedback controllers distributed throughout the network which respond to disturbances in real time. In this paper, we demonstrate that VPC can actively manage distributed energy resources to avoid voltage magnitude and line flow constraint violations in power distribution networks. We provide sensitivities and bounds that quantify how the distributed voltage phasor feedback control reduces the effect of disturbances on the network voltages and line flows. Using simulations, we compare the performance of VPC with the related but more conventional Voltage Magnitude Control (VMC). The sensitivities, bounds, and simulations provide implementation insights, which we highlight, for how distribution network operators can use VPC and VMC to avoid constraint violations.

preprint2021arXiv

Guaranteed Phase & Topology Identification in Three Phase Distribution Grids

We present a method for joint phase identification and topology recovery in unbalanced three phase radial networks using only voltage measurements. By recovering phases and topology jointly, we utilize all three phase voltage measurements and can handle networks where some buses have a subset of three phases. Our method is theoretically justified by a novel linearized formulation of unbalanced three phase power flow and makes precisely defined and reasonable assumptions on line impedances and load statistics. We validate our method on three IEEE test networks simulated under realistic conditions in OpenDSS, comparing our performance to the state of the art. In addition to providing a new method for phase and topology recovery, our intuitively structured linearized model will provide a foundation for future work in this and other applications.

preprint2017arXiv

On Identification of Distribution Grids

Large-scale integration of distributed energy resources into residential distribution feeders necessitates careful control of their operation through power flow analysis. While the knowledge of the distribution system model is crucial for this type of analysis, it is often unavailable or outdated. The recent introduction of synchrophasor technology in low-voltage distribution grids has created an unprecedented opportunity to learn this model from high-precision, time-synchronized measurements of voltage and current phasors at various locations. This paper focuses on joint estimation of model parameters (admittance values) and operational structure of a poly-phase distribution network from the available telemetry data via the lasso, a method for regression shrinkage and selection. We propose tractable convex programs capable of tackling the low rank structure of the distribution system and develop an online algorithm for early detection and localization of critical events that induce a change in the admittance matrix. The efficacy of these techniques is corroborated through power flow studies on four three-phase radial distribution systems serving real household demands.

preprint2016arXiv

Event Detection and Localization in Distribution Grids with Phasor Measurement Units

The recent introduction of synchrophasor technology into power distribution systems has given impetus to various monitoring, diagnostic, and control applications, such as system identification and event detection, which are crucial for restoring service, preventing outages, and managing equipment health. Drawing on the existing framework for inferring topology and admittances of a power network from voltage and current phasor measurements, this paper proposes an online algorithm for event detection and localization in unbalanced three-phase distribution systems. Using a convex relaxation and a matrix partitioning technique, the proposed algorithm is capable of identifying topology changes and attributing them to specific categories of events. The performance of this algorithm is evaluated on a standard test distribution feeder with synthesized loads, and it is shown that a tripped line can be detected and localized in an accurate and timely fashion, highlighting its potential for real-world applications.