Source author record

Alexandra von Meier

Alexandra von Meier appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

13works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

13 published item(s)

preprint2022arXiv

Parameter Conditions to Prevent Voltage Oscillations Caused by LTC-Inverter Hunting on Power Distribution Grids

As more distributed energy resources (DERs) are connected to the power grid, it becomes increasingly important to ensure safe and effective coordination between legacy voltage regulation devices and inverter-based DERs. In this work, we show how a distribution circuit model, composed of two LTCs and two inverter devices, can create voltage oscillations even with reasonable choices of control parameters. By modeling the four-device circuit as a switched affine hybrid system, we analyze the system's oscillatory behavior, both during normal operation and after a cyber-physical attack. Through the analysis we determine the specific region of the voltage state space where oscillations are possible and derive conditions on the control parameters to guarantee against the oscillations. Finally, we project the derived parameter conditions onto 2D spaces, and describe the application of our problem formulation to grids with many devices.

preprint2022arXiv

Using Voltage Phasor Control to Avoid Distribution Network Constraint Violations

In this paper, we introduce Voltage Phasor Control (VPC), also known as Phasor Based Control, as a novel way of implementing Optimal Power Flow (OPF). Unlike conventional OPF, in which the power flow optimization broadcasts power injections, the VPC power flow optimization broadcasts voltage phasor setpoints to feedback controllers distributed throughout the network which respond to disturbances in real time. In this paper, we demonstrate that VPC can actively manage distributed energy resources to avoid voltage magnitude and line flow constraint violations in power distribution networks. We provide sensitivities and bounds that quantify how the distributed voltage phasor feedback control reduces the effect of disturbances on the network voltages and line flows. Using simulations, we compare the performance of VPC with the related but more conventional Voltage Magnitude Control (VMC). The sensitivities, bounds, and simulations provide implementation insights, which we highlight, for how distribution network operators can use VPC and VMC to avoid constraint violations.

preprint2021arXiv

Guaranteed Phase & Topology Identification in Three Phase Distribution Grids

We present a method for joint phase identification and topology recovery in unbalanced three phase radial networks using only voltage measurements. By recovering phases and topology jointly, we utilize all three phase voltage measurements and can handle networks where some buses have a subset of three phases. Our method is theoretically justified by a novel linearized formulation of unbalanced three phase power flow and makes precisely defined and reasonable assumptions on line impedances and load statistics. We validate our method on three IEEE test networks simulated under realistic conditions in OpenDSS, comparing our performance to the state of the art. In addition to providing a new method for phase and topology recovery, our intuitively structured linearized model will provide a foundation for future work in this and other applications.

preprint2017arXiv

On Identification of Distribution Grids

Large-scale integration of distributed energy resources into residential distribution feeders necessitates careful control of their operation through power flow analysis. While the knowledge of the distribution system model is crucial for this type of analysis, it is often unavailable or outdated. The recent introduction of synchrophasor technology in low-voltage distribution grids has created an unprecedented opportunity to learn this model from high-precision, time-synchronized measurements of voltage and current phasors at various locations. This paper focuses on joint estimation of model parameters (admittance values) and operational structure of a poly-phase distribution network from the available telemetry data via the lasso, a method for regression shrinkage and selection. We propose tractable convex programs capable of tackling the low rank structure of the distribution system and develop an online algorithm for early detection and localization of critical events that induce a change in the admittance matrix. The efficacy of these techniques is corroborated through power flow studies on four three-phase radial distribution systems serving real household demands.

preprint2016arXiv

Event Detection and Localization in Distribution Grids with Phasor Measurement Units

The recent introduction of synchrophasor technology into power distribution systems has given impetus to various monitoring, diagnostic, and control applications, such as system identification and event detection, which are crucial for restoring service, preventing outages, and managing equipment health. Drawing on the existing framework for inferring topology and admittances of a power network from voltage and current phasor measurements, this paper proposes an online algorithm for event detection and localization in unbalanced three-phase distribution systems. Using a convex relaxation and a matrix partitioning technique, the proposed algorithm is capable of identifying topology changes and attributing them to specific categories of events. The performance of this algorithm is evaluated on a standard test distribution feeder with synthesized loads, and it is shown that a tripped line can be detected and localized in an accurate and timely fashion, highlighting its potential for real-world applications.

preprint2015arXiv

A Unified Platform Enabling Power System Circuit Model Data Transfer Among Different Software

Diversity of software packages to simulate the power system circuits is considerable. It is challenging to transfer power system circuit model data (PSCMD) among different software tools and rebuild the same circuit in the second software environment. This paper proposes a unified platform (UP) where PSCMD are stored in a spreadsheet file with a defined format. Script-based PSCMD transfer applications, written in MATLAB, have been developed for a set of software to read the circuit model data from the UP spreadsheet and reconstruct the circuit in the destination software. This significantly eases the process of transferring circuit model data between each pair of software tools. In this paper ETAP, OpenDSS, Grid LabD, and DEW are considered. In order to test the developed PSCMD transfer applications, circuit model data of a test circuit and an actual sample circuit from a Californian utility company, both built in CYME, were exported into the spreadsheet file according to the UP format. Thereafter, circuit model data were imported successfully from the spreadsheet files into all above mentioned software using the PSCMD transfer applications developed for each software individually. Finally, load flow analysis is performed in all software and the obtained results match with each other.

preprint2015arXiv

Data-Driven Approach for Distribution Network Topology Detection

This paper proposes a data-driven approach to detect the switching actions and topology transitions in distribution networks. It is based on the real time analysis of time-series voltages measurements. The analysis approach draws on data from high-precision phasor measurement units ($μ$PMUs or synchrophasors) for distribution networks. The key fact is that time-series measurement data taken from the distribution network has specific patterns representing state transitions such as topology changes. The proposed algorithm is based on comparison of actual voltage measurements with a library of signatures derived from the possible topologies simulation. The IEEE 33-bus model is used for the algorithm validation.

preprint2015arXiv

Distribution Network Topology Detection with Time Series Measurement Data Analysis

This paper proposes a novel approach for detecting the topology of distribution networks based on the analysis of time series measurements. The time-based analysis approach draws on data from high-precision phasor measurement units (PMUs or synchrophasors) for distribution systems. A key fact is that time-series data taken from a dynamic system show specific patterns regarding state transitions such as opening or closing switches, as a kind of signature from each topology change. The proposed algorithm here is based on the comparison of the actual signature of a recent state transition against a library of signatures derived from topology simulations. The IEEE 33-bus model is used for initial algorithm validation.

preprint2015arXiv

On the Definition of Cyber-Physical Resilience in Power Systems

In recent years, advanced sensors, intelligent automation, communication networks, and information technologies have been integrated into the electric grid to enhance its performance and efficiency. Integrating these new technologies has resulted in more interconnections and interdependencies between the physical and cyber components of the grid. Natural disasters and man-made perturbations have begun to threaten grid integrity more often. Urban infrastructure networks are highly reliant on the electric grid and consequently, the vulnerability of infrastructure networks to electric grid outages is becoming a major global concern. In order to minimize the economic, social, and political impacts of power system outages, the grid must be resilient. The concept of a power system cyber-physical resilience centers around maintaining system states at a stable level in the presence of disturbances. Resilience is a multidimensional property of the electric grid, it requires managing disturbances originating from physical component failures, cyber component malfunctions, and human attacks. In the electric grid community, there is not a clear and universally accepted definition of cyber-physical resilience. This paper focuses on the definition of resilience for the electric grid and reviews key concepts related to system resilience. This paper aims to advance the field not only by adding cyber-physical resilience concepts to power systems vocabulary, but also by proposing a new way of thinking about grid operation with unexpected disturbances and hazards and leveraging distributed energy resources.

preprint2015arXiv

Phase Identification in Distribution Networks with Micro-Synchrophasors

This paper proposes a novel phase identification method for distribution networks where phases can be severely unbalanced and insufficiently labeled. The analysis approach draws on data from high-precision phasor measurement units (micro-synchrophasors or uPMUs) for distribution systems. A key fact is that time-series voltage phasors taken from a distribution network show specific patterns regarding connected phases at measurement points. The algorithm is based on analyzing crosscorrelations over voltage magnitudes along with phase angle differences on two candidate phases to be matched. If two measurement points are on the same phase, large positive voltage magnitude correlations and small voltage angle differences should be observed. The algorithm is initially validated using the IEEE 13-bus model, and subsequently with actual uPMU measurements on a 12-kV feeder.

preprint2015arXiv

Topology Detection in Microgrids with Micro-Synchrophasors

Network topology in distribution networks is often unknown, because most switches are not equipped with measurement devices and communication links. However, knowledge about the actual topology is critical for safe and reliable grid operation. This paper proposes a voting-based topology detection method based on micro-synchrophasor measurements. The minimal difference between measured and calculated voltage angle or voltage magnitude, respectively, indicates the actual topology. Micro-synchrophasors or micro-Phasor Measurement Units (μPMU) are high-precision devices that can measure voltage angle differences on the order of ten millidegrees. This accuracy is important for distribution networks due to the smaller angle differences as compared to transmission networks. For this paper, a microgrid test bed is implemented in MATLAB with simulated measurements from μPMUs as well as SCADA measurement devices. The results show that topologies can be detected with high accuracy. Additionally, topology detection by voltage angle shows better results than detection by voltage magnitude.

preprint2014arXiv

Chapter 34 - Every Moment Counts: Synchrophasors for Distribution Networks with Variable Resources

Historically, with mostly radial power distribution and one-way power flow, it was only necessary to evaluate the envelope of design conditions, e.g., peak loads or fault currents, rather than continually observe the operating state. But the growth of distributed energy resources introduces variability, uncertainty, and opportunities to recruit diverse resources for grid services. This chapter addresses how the direct measurement of voltage phase angle might enable new strategies for managing distribution networks with diverse, active components.

preprint2014arXiv

Phasor-Based Approach for Harmonic Assessment from Multiple Distributed Energy Resources

This paper analyzes impacts and interactions of harmonics from multiple sources, especially distributed energy resources, on distribution networks. We propose a new index, the Phasor Harmonic Index (PHI), that considers both harmonic source magnitude and phase angle, while other commonly used harmonic indices are based solely on magnitude of waveforms. The use of such an index becomes feasible and practical through emerging monitoring technologies like micro-Synchrophasors in distribution networks that help measure and visualize voltage and current phase angles along with their magnitudes. A very detailed model of a distribution network is also needed for the harmonic interaction assessment in this paper.