A few comments to a method for producing positrons for ILC
We attracted attention to some peculiarities of positron production for linear collider (ILC). The conversion system with many targets and low K-factor is our primary interest.
Discover
Research tools
Network
Opportunities
Account
Source author record
Alexander Mikhailichenko appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.
Catalog footprint
Research graph
Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.
BZPEER is loading the nearby papers, people, topics and institutions for this page.
Published work
We attracted attention to some peculiarities of positron production for linear collider (ILC). The conversion system with many targets and low K-factor is our primary interest.
We describe here a compact gantry system, when the lying patient is slowly moved in horizontal and vertical directions in accordance with rotation of transport channel around its axis so that the region, irradiated from different directions, stays in a focus of beam optical system. By this combination of rotation of magnets and linear motion of patient it becomes possible to simplify magnetic system significantly.
We discuss the basis of polarized positron production by low energy polarized electrons. Efficiency of conversion ~0.1-1% might be interesting for CEBAF facility and ILC as well.
For low energy operation strategy we advocate utilization of many short wigglers in contrast with single long wiggler. This allows begin to operate very naturally with few strong field wigglers giving necessary damping time on expense of energy spread. By adding more and more wigglers in the ring, as these wigglers are manufactured and tuned, the field in the wigglers will be decreased, keeping necessary damping. This strategy allows the mostly effective operation of CESR with minimum down time. This also gives flexibility in operation in wider energy scale without non-reversible modifications.
We revise a possibility of usage iron-free fast pulsed magnet as inflector for g-2 ring, coming to conclusion that it is a feasible option.
We consider a single solenoidal system for possible usage in Iron-free detectors for future linear colliders
In this publication we collected descriptions of some installations with liquid metals which could be used for high-energy colliders, ILC particularly, for the purposes of targeting, collimation, cooling, collection of secondary particles etc. Some important components of the system with liquid metals, such as pumps, nozzles, windows, and the fluid dynamics in the Lithium lens are described also.
We are considering usage of gas-filled mechanical relays-Kilovacs and Gigavacs- for power supply of HV electrical dipoles, quadrupoles etc., where even a time dependent regime required. One can expect the physical switching time on few nanosecond level with such devices operating up to 70kV with currents~50A.
We continue consideration of Iron-free magnetic systems for possible application in detectors for high energy collider. In particular we suggest a new type of magnetic system with the multiple flux-return solenoids. This system allows reaching higher field level at IP compared with traditional ones.
We describe another detectora designed for the International Linear Collider based on several tested instrumentation innovations in order to achieve the necessary experi- mental goal of a detecter that is 2-to-10 times better than the already excellent SLC and LEP detectors, in particular, (1) dual-readout calorimeter system based on the RD52/DREAM measurements at CERN, (2) a cluster-counting drift chamber based on the successful kloe chamber at Frascati, and (3) a second solenoid to return the magnetic flux without iron. A high-performance pixel vertex chamber is presently undefined. We discuss particle identification, momentum and energy resolutions, and the machine-detector interface that together offer the possibility of a very high-performance detector for $e^+e^-$physics up to $\sqrt{s} = 1$ TeV.