Researcher profile

Alessandro Valiani

Alessandro Valiani contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Modeling blood flow in networks of viscoelastic vessels with the 1-D augmented fluid-structure interaction system

A noteworthy aspect in blood flow modeling is the definition of the mechanical interaction between the fluid flow and the biological structure that contains it, namely the vessel wall. It has been demonstrated that the addition of a viscous contribution to the mechanical characterization of vessels brings positive results when compared to in-vivo measurements. In this context, the numerical implementation of boundary conditions able to keep memory of the viscoelastic contribution of vessel walls assumes an important role, especially when dealing with large circulatory systems. In this work, viscoelasticity is taken into account in entire networks via the Standard Linear Solid Model. The implementation of the viscoelastic contribution at boundaries (inlet, outlet and junctions), is carried out considering the hyperbolic nature of the mathematical model. A non-linear system is established based on the definition of the Riemann Problem at junctions, characterized by rarefaction waves separated by contact discontinuities, among which the mass and the total energy are conserved. Basic junction tests are analyzed, such as a trivial 2-vessels junction, for both a generic artery and vein, and a simple 3-vessels junction, considering an aortic bifurcation scenario. The chosen asymptotic-preserving IMEX Runge-Kutta Finite Volume scheme is demonstrated to be second-order accurate in the whole domain and well-balanced, even when including junctions. Two different benchmark models of the arterial network are implemented, differing in number of vessels and in viscoelastic parameters. Comparison of the results obtained in the two networks underlines the high sensitivity of the model to the chosen viscoelastic parameters. The conservation of the contribution provided by the viscoelastic characterization of vessel walls is assessed in the whole network, including junctions and boundary conditions.

preprint2020arXiv

Uncertainty quantification of viscoelastic parameters in arterial hemodynamics with the a-FSI blood flow model

This work aims at identifying and quantifying uncertainties related to elastic and viscoelastic parameters, which characterize the arterial wall behavior, in one-dimensional modeling of the human arterial hemodynamics. The chosen uncertain parameters are modeled as random Gaussian-distributed variables, making stochastic the system of governing equations. The proposed methodology is initially validated on a model equation, presenting a thorough convergence study which confirms the spectral accuracy of the stochastic collocation method and the second-order accuracy of the IMEX finite volume scheme chosen to solve the mathematical model. Then, univariate and multivariate uncertain quantification analyses are applied to the a-FSI blood flow model, concerning baseline and patient-specific single-artery test cases. A different sensitivity is depicted when comparing the variability of flow rate and velocity waveforms to the variability of pressure and area, the latter ones resulting much more sensitive to the parametric uncertainties underlying the mechanical characterization of vessel walls. Simulations performed considering both the simple elastic and the more realistic viscoelastic constitutive law show that the great uncertainty of the viscosity parameter plays a major role in the prediction of pressure waveforms, enlarging the confidence interval of this variable. In-vivo recorded patient-specific pressure data falls within the confidence interval of the output obtained with the proposed methodology and expectations of the computed pressures are comparable to the recorded waveforms.

preprint2019arXiv

Mathematical study of linear morphodynamic acceleration and derivation of the MASSPEED approach

Morphological accelerators, such as the MORFAC (MORphological acceleration FACtor) approach, are widely adopted techniques for the acceleration of the bed evolution, which reduces the computational cost of morphodynamic numerical simulations. In this work we apply a non-uniform acceleration to the one-dimensional morphodynamic problem described by the de Saint Venant-Exner model by multiplying all the spatial derivatives by an individual constant (>1) acceleration factor. The final goal is to identify the best combination of the three accelerating factors for which i) the bed responds linearly to hydrodynamic changes; ii) a consistent decrease of the computational cost is obtained. The sought combination is obtained by studying the behaviour of an approximate solution of the three eigenvalues associated with the flux matrix of the accelerated system. This approach allows to derive a new linear morphodynamic acceleration technique, the MASSPEED (MASs equations SPEEDup) approach, and the a priori determination of the highest acceleration allowed for a given simulation. In this new approach both mass conservation equations (water and sediment) are accelerated by the same factor, differently from the MORFAC approach where only the sediment mass equation is modified. The analysis shows that the MASSPEED gives a larger validity range for linear acceleration and requires smaller computational costs than that of the classical MORFAC approach. The MASSPEED approach is implemented within an example code, using an adaptive approach that applies the maximum linear acceleration similarly to the Courant-Friedrichs-Lewy stability condition. Finally, numerical simulations have been performed in order to assess the accuracy and efficiency of the new approach. Results obtained in the long-term propagation of a sediment hump demonstrate the advantages of the new approach.