Researcher profile

Albert Vexler

Albert Vexler contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
2topics
3close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2020arXiv

Valid p-Values and Expectations of p-Values Revisited

A storm of favorable or critical publications regarding p-values-based procedures has been observed in both the theoretical and applied literature. We focus on valid definitions of p-values in the scenarios when composite null models are in effect. A valid p-value (VpV) statistic can be used to make a prefixed level-decision. In this context, Kolmogorov Smirnov goodness-of-fit tests and the normal two sample problem are considered. In particular, we examine an issue regarding the goodness-of-fit testability based on a single observation. This article exemplifies constructions of new test procedures, advocating practical reasons to implement VpV-based mechanisms. The VpV framework induces an extension of the conventional expected p-value (EPV) tool for measuring the performance of a test. Associating the EPV concept with the receiver operating characteristic (ROC) curve methodology, a well-established biostatistical approach, we propose a Youden index based optimality principle to derive critical values of decision making procedures. In these terms, the significance level alpha=0.05 can be suggested, in many situations. In light of an ROC curve analysis, we introduce partial EPVs to characterize properties of tests including their unbiasedness. We also provide the intrinsic relationship between the Bayes Factor (BF) test statistic and the BF of test statistics. Keywords: AUC; Bayes Factor; Expected p-value; Kolmogorov Smirnov tests; Likelihood ratio; Nuisance parameters; P-value; ROC curve; Pooled data; Single observation; Type I error rate; Youden index

preprint2012arXiv

A combined efficient design for biomarker data subject to a limit of detection due to measuring instrument sensitivity

Pooling specimens, a well-accepted sampling strategy in biomedical research, can be applied to reduce the cost of studying biomarkers. Even if the cost of a single assay is not a major restriction in evaluating biomarkers, pooling can be a powerful design that increases the efficiency of estimation based on data that is censored due to an instrument's lower limit of detection (LLOD). However, there are situations when the pooling design strongly aggravates the detection limit problem. To combine the benefits of pooled assays and individual assays, hybrid designs that involve taking a sample of both pooled and individual specimens have been proposed. We examine the efficiency of these hybrid designs in estimating parameters of two systems subject to a LLOD: (1) normally distributed biomarker with normally distributed measurement error and pooling error; (2) Gamma distributed biomarker with double exponentially distributed measurement error and pooling error. Three-assay design and two-assay design with replicates are applied to estimate the measurement and pooling error. The Maximum likelihood method is used to estimate the parameters. We found that the simple one-pool design, where all assays but one are random individuals and a single pooled assay includes the remaining specimens, under plausible conditions, is very efficient and can be recommended for practical use.