Researcher profile

Aijun Ye

Aijun Ye contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 11 - UnverifiedVerification L1Unclaimed author
1works
0followers
1topics
3close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2012arXiv

A combined efficient design for biomarker data subject to a limit of detection due to measuring instrument sensitivity

Pooling specimens, a well-accepted sampling strategy in biomedical research, can be applied to reduce the cost of studying biomarkers. Even if the cost of a single assay is not a major restriction in evaluating biomarkers, pooling can be a powerful design that increases the efficiency of estimation based on data that is censored due to an instrument's lower limit of detection (LLOD). However, there are situations when the pooling design strongly aggravates the detection limit problem. To combine the benefits of pooled assays and individual assays, hybrid designs that involve taking a sample of both pooled and individual specimens have been proposed. We examine the efficiency of these hybrid designs in estimating parameters of two systems subject to a LLOD: (1) normally distributed biomarker with normally distributed measurement error and pooling error; (2) Gamma distributed biomarker with double exponentially distributed measurement error and pooling error. Three-assay design and two-assay design with replicates are applied to estimate the measurement and pooling error. The Maximum likelihood method is used to estimate the parameters. We found that the simple one-pool design, where all assays but one are random individuals and a single pooled assay includes the remaining specimens, under plausible conditions, is very efficient and can be recommended for practical use.