Researcher profile

Albert Hirtl

Albert Hirtl contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 11 - UnverifiedVerification L1Unclaimed author
1works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2021arXiv

Feasibility study of a proton CT system based on 4D-tracking and residual energy determination via time-of-flight

For dose calculations in ion beam therapy, it is vital to accurately determine the relative stopping power (RSP) distribution within the treated volume. Currently, RSP values are extrapolated from Hounsfield units (HU), measured with x-ray computed tomography (CT), which entails RSP inaccuracies due to conversion errors. A suitable method to improve the treatment plan accuracy is proton computed tomography (pCT). A typical pCT system consists of a tracking system and a separate residual energy (or range) detector to measure the RSP distribution directly. This paper introduces a novel pCT system based on a single detector technology, namely low gain avalanche detectors (LGADs). LGADs are fast 4D-tracking detectors, which can be used to simultaneously measure the particle position and time with precise timing and spatial resolution. In contrast to standard pCT systems, the residual energy is determined via a time-of-flight (TOF) measurement between different 4D-tracking stations. The design parameters for a realistic proton computed tomography system based on 4D-tracking detectors were studied and optimized using Monte Carlo simulations. The RSP accuracy and RSP resolution were measured inside the inserts of the CTP404 phantom to estimate the performance of the pCT system. After introducing a dedicated calibration procedure for the TOF calorimeter, RSP accuracies < 0.6 % could be achieved. Furthermore, the design parameters with the strongest impact on the RSP resolution were identified and a strategy to improve RSP resolution is proposed.