Source author record

Alan E. Robinson

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

4works
8topics
1close collaborators

Published work

4 publications

preprint2020arXiv

XENON1T observes tritium

XENON1T recently reported an excess of low-energy electron recoil events that may be attributable to either new physics or to the radioactive decay of tritium. It is likely that hydrogen is not be effectively removed by the hot zirconium getters deployed in the detector. Cosmogenic activation of the xenon underground is found to be insufficient to describe the observed excess, although gases diffusing out of detector materials from cosmogenic activation on surface may contribute. Changes in the operation of gas purification systems for XENON1T and other liquid nobel gas detectors could both confirm the tritium hypothesis and remove it from the detector.

preprint2016arXiv

A reanalysis of radioisotope measurements of the 9^9Be(γ,n)8(γ,n)^8Be cross-section

The 9^9Be(γ,n)8(γ,n)^8Be reaction is enhanced by a near threshold 1/2+1/2^+ state. Contradictions between existing measurements of this reaction cross-section affect calculations of astrophysical r-process yields, dark matter detector calibrations, and the theory of the nuclear structure of 9^9Be. Select well-documented radioisotope 9^9Be(γ,n)(γ,n) source yield measurements have been reanalyzed, providing a set of high-accuracy independently measured cross sections. A Breit-Wigner fit of these corrected measurements yields ER=1738.8±1.9E_R=1738.8\pm1.9 keV, Γγ=0.771±0.021Γ_γ=0.771\pm0.021 eV, and Γn=268±15Γ_n=268\pm15 keV for the 1/2+1/2^+ state. A virtual 1/2+1/2^+ state is excluded with 99.3\% confidence.

preprint2014arXiv

New libraries for simulating neutron scattering in dark matter detector calibrations

Dark matter detectors require calibrations of their energy scale and efficiency to detect nuclear recoils in the 1−501-50 keV range. Most calibrations use neutron scattering and require MCNP or Geant4 simulations of neutron propagation through the detector. For most nuclei heavier than 16^{16}O, these simulations' libraries ignore the contribution of resolved resonances to the neutron elastic differential cross-section. For many isotopes and neutron energies of importance to dark matter detection, this invalid assumption can severely distort simulated nuclear recoil spectra. The correct angular distributions can be calculated from the resonance parameters using R-matrix formalism. A set of neutron scattering libraries with high resolution angular distributions for MCNP and Geant4 of 19^{19}F, 40^{40}Ar, 50,52^{50,52}Cr, 56^{56}Fe, 136^{136}Xe, and 206,207,208^{206,207,208}Pb is presented. An MCNPX library for simulating the production of low-energy neutrons in the 9^9Be(γ,n)8(γ,n)^8Be reaction is also presented. Example dark matter detector calibrations are simulated with the new libraries showing how detector sensitivity could be overestimated by factors of two by relying on existing MCNP and Geant4 libraries.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.