Source author record

Akira Okumura

Akira Okumura appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

9works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2022arXiv

Calibration and performance of the readout system based on switched capacitor arrays for the Large-Sized Telescope of the Cherenkov Telescope Array

The Cherenkov Telescope Array (CTA) is the next-generation ground-based very-high-energy gamma-ray observatory. The Large-Sized Telescope (LST) of CTA is designed to detect gamma rays between 20 GeV and a few TeV with a 23-meter diameter mirror. We have developed the focal plane camera of the first LST, which has 1855 photomultiplier tubes (PMTs) and the readout system which samples a PMT waveform at GHz with switched capacitor arrays, Domino Ring Sampler ver4 (DRS4). To measure the precise pulse charge and arrival time of Cherenkov signals, we developed a method to calibrate the output voltage of DRS4 and the sampling time interval, as well as an analysis method to correct the spike noise of DRS4. Since the first LST was inaugurated in 2018, we have performed the commissioning tests and calibrated the camera. We characterised the camera in terms of the charge pedestal under various conditions of the night sky background, the charge resolution of each pixel, the charge uniformity of the whole camera, and the time resolutions with a test pulse and calibration laser.

preprint2022arXiv

Design and Performance of the Prototype Schwarzschild-Couder Telescope Camera

The prototype Schwarzschild-Couder Telescope (pSCT) is a candidate for a medium-sized telescope in the Cherenkov Telescope Array. The pSCT is based on a novel dual mirror optics design which reduces the plate scale and allows for the use of silicon photomultipliers as photodetectors. The prototype pSCT camera currently has only the central sector instrumented with 25 camera modules (1600 pixels), providing a 2.68$^{\circ}$ field of view (FoV). The camera electronics are based on custom TARGET (TeV array readout with GSa/s sampling and event trigger) application specific integrated circuits. Field programmable gate arrays sample incoming signals at a gigasample per second. A single backplane provides camera-wide triggers. An upgrade of the pSCT camera is in progress, which will fully populate the focal plane. This will increase the number of pixels to 11,328, the number of backplanes to 9, and the FoV to 8.04$^{\circ}$. Here we give a detailed description of the pSCT camera, including the basic concept, mechanical design, detectors, electronics, current status and first light.

preprint2019arXiv

Characterization of SiPM Optical Crosstalk and its Dependence on the Protection-Window Thickness

Owing to their high photon detection efficiency, compactness, and low operating voltage, silicon photomultipliers (SiPMs) have found widespread application in many fields, including medical imaging, particle physics, and high-energy astrophysics. However, the so-called optical crosstalk (OCT) phenomenon of SiPMs is a major drawback to their adoption. Secondary infrared photons are emitted inside the silicon substrate spontaneously after the avalanche process caused by the primary incident photons, and they can be detected by the surrounding photodiodes. As a result large output pulses that are equivalent to multiple photoelectrons are observed with a certain probability (OCT rate), even for single-photon events, making the charge resolution worse and increasing the rate of accidental triggers by single-photon events in applications such as atmospheric Cherenkov telescopes. In our previous study, we found that the OCT rates of single-channel SiPMs was dependent on the thickness of their protection resin window, which may be explained by photon propagation inside the resin. In the present study, we measured the OCT rate of a multichannel SiPM and those of neighboring channels caused by photon propagation. Both OCT rates were found to be dependent on the protection-window thickness. We report our OCT measurements of a multichannel SiPM and comparisons with a ray-tracing simulation.

preprint2019arXiv

Development of a UV-transparent Lens Array for Enlarging the Effective Area of Multichannel SiPMs

We developed a UV-transparent lens array that can increase the photon detection efficiency of a silicon photomultiplier (SiPM) array comprising of 64 pixels ($3\times3$ mm$^2$ each) and 0.2-mm gaps. Through the plano-convex spherical lens on each $3.2\times3.2$ mm$^2$ region, we showed that the loss of photon detection efficiency due to the pixel gaps could be recovered as the incident photons get concentrated on the sensitive regions of the SiPM array. By using a prototype lens array, we achieved approximately 10%-30% relative increase in photon detection efficiency in our target angles of incidence of 30-60 deg.

preprint2015arXiv

Prototyping of Hexagonal Light Concentrators for the Large-Sized Telescopes of the Cherenkov Telescope Array

Reflective light concentrators with hexagonal entrance and exit apertures are frequently used at the focal plane of gamma-ray telescopes in order to reduce the size of the dead area caused by the geometries of the photodetectors, as well as to reduce the amount of stray light entering at large field angles. The focal plane of the large-sized telescopes (LSTs) of the Cherenkov Telescope Array (CTA) will also be covered by hexagonal light concentrators with an entrance diameter of 50 mm (side to side) to maximize the active area and the photon collection efficiency, enabling realization of a very low energy threshold of 20 GeV. We have developed a prototype of this LST light concentrator with an injection-molded plastic cone and a specular multilayer film. The shape of the plastic cone has been optimized with a cubic Bézier curve and a ray-tracing simulation. We have also developed a multilayer film with very high reflectance ($\gtrsim95$\%) along wide wavelength and angle coverage. The current status of the prototyping of these light concentrators is reported here.

preprint2015arXiv

ROBAST: Development of a Non-Sequential Ray-Tracing Simulation Library and its Applications in the Cherenkov Telescope Array

We have developed a non-sequential ray-tracing simulation library, ROot-BAsed Simulator for ray Tracing (ROBAST), which is aimed for wide use in optical simulations of cosmic-ray (CR) and gamma-ray telescopes. The library is written in C++ and fully utilizes the geometry library of the ROOT analysis framework. Despite the importance of optics simulations in CR experiments, no open-source software for ray-tracing simulations that can be widely used existed. To reduce the unnecessary effort demanded when different research groups develop multiple ray-tracing simulators, we have successfully used ROBAST for many years to perform optics simulations for the Cherenkov Telescope Array (CTA). Among the proposed telescope designs for CTA, ROBAST is currently being used for three telescopes: a Schwarzschild--Couder telescope, one of the Schwarzschild--Couder small-sized telescopes, and a large-sized telescope (LST). ROBAST is also used for the simulations and the development of hexagonal light concentrators that has been proposed for the LST focal plane. By fully utilizing the ROOT geometry library with additional ROBAST classes, building complex optics geometries that are typically used in CR experiments and ground-based gamma-ray telescopes is possible. We introduce ROBAST and show several successful applications for CTA.

preprint2015arXiv

ROBAST: Development of a ROOT-Based Ray-Tracing Library for Cosmic-Ray Telescopes and its Applications in the Cherenkov Telescope Array

We have developed a non-sequential ray-tracing simulation library, ROOT-based simulator for ray tracing (ROBAST), which is aimed to be widely used in optical simulations of cosmic-ray (CR) and gamma-ray telescopes. The library is written in C++, and fully utilizes the geometry library of the ROOT framework. Despite the importance of optics simulations in CR experiments, no open-source software for ray-tracing simulations that can be widely used in the community has existed. To reduce the dispensable effort needed to develop multiple ray-tracing simulators by different research groups, we have successfully used ROBAST for many years to perform optics simulations for the Cherenkov Telescope Array (CTA). Among the six proposed telescope designs for CTA, ROBAST is currently used for three telescopes: a Schwarzschild-Couder (SC) medium-sized telescope, one of SC small-sized telescopes, and a large-sized telescope (LST). ROBAST is also used for the simulation and development of hexagonal light concentrators proposed for the LST focal plane. Making full use of the ROOT geometry library with additional ROBAST classes, we are able to build the complex optics geometries typically used in CR experiments and ground-based gamma-ray telescopes. We introduce ROBAST and its features developed for CR experiments, and show several successful applications for CTA.

preprint2012arXiv

Optimization of the Collection Efficiency of a Hexagonal Light Collector using Quadratic and Cubic Bézier Curves

Reflective light collectors with hexagonal entrance and exit apertures are frequently used in front of the focal-plane camera of a very-high-energy gamma-ray telescope to increase the collection efficiency of atmospheric Cherenkov photons and reduce the night-sky background entering at large incident angles. The shape of a hexagonal light collector is usually based on Winston's design, which is optimized for only two-dimensional optical systems. However, it is not known whether a hexagonal Winston cone is optimal for the real three-dimensional optical systems of gamma-ray telescopes. For the first time we optimize the shape of a hexagonal light collector using quadratic and cubic Bézier curves. We demonstrate that our optimized designs simultaneously achieve a higher collection efficiency and background reduction rate than traditional designs.

preprint2011arXiv

Development of Non-sequential Ray-tracing Software for Cosmic-ray Telescopes

We have developed non-sequential ray-tracing software which is aimed to be widely used, along with air- shower simulations, in the design of optical systems for cosmic-ray experiments. The code is based on the ROOT geometry library to provide a non-sequential photon tracking system, which is valuable when simulating refraction and multiple reflections. In addition to the basic ROOT classes, we have implemented new geometry ROOT classes so that users can flexibly define various geometries such as aspherical or Winston-cone type surfaces. We demonstrate the capabilities and performance of the software with examples of optical systems used in current and future experiments.