Researcher profile

Akira Okumura

Akira Okumura contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Calibration and performance of the readout system based on switched capacitor arrays for the Large-Sized Telescope of the Cherenkov Telescope Array

The Cherenkov Telescope Array (CTA) is the next-generation ground-based very-high-energy gamma-ray observatory. The Large-Sized Telescope (LST) of CTA is designed to detect gamma rays between 20 GeV and a few TeV with a 23-meter diameter mirror. We have developed the focal plane camera of the first LST, which has 1855 photomultiplier tubes (PMTs) and the readout system which samples a PMT waveform at GHz with switched capacitor arrays, Domino Ring Sampler ver4 (DRS4). To measure the precise pulse charge and arrival time of Cherenkov signals, we developed a method to calibrate the output voltage of DRS4 and the sampling time interval, as well as an analysis method to correct the spike noise of DRS4. Since the first LST was inaugurated in 2018, we have performed the commissioning tests and calibrated the camera. We characterised the camera in terms of the charge pedestal under various conditions of the night sky background, the charge resolution of each pixel, the charge uniformity of the whole camera, and the time resolutions with a test pulse and calibration laser.

preprint2022arXiv

Design and Performance of the Prototype Schwarzschild-Couder Telescope Camera

The prototype Schwarzschild-Couder Telescope (pSCT) is a candidate for a medium-sized telescope in the Cherenkov Telescope Array. The pSCT is based on a novel dual mirror optics design which reduces the plate scale and allows for the use of silicon photomultipliers as photodetectors. The prototype pSCT camera currently has only the central sector instrumented with 25 camera modules (1600 pixels), providing a 2.68$^{\circ}$ field of view (FoV). The camera electronics are based on custom TARGET (TeV array readout with GSa/s sampling and event trigger) application specific integrated circuits. Field programmable gate arrays sample incoming signals at a gigasample per second. A single backplane provides camera-wide triggers. An upgrade of the pSCT camera is in progress, which will fully populate the focal plane. This will increase the number of pixels to 11,328, the number of backplanes to 9, and the FoV to 8.04$^{\circ}$. Here we give a detailed description of the pSCT camera, including the basic concept, mechanical design, detectors, electronics, current status and first light.

preprint2019arXiv

Characterization of SiPM Optical Crosstalk and its Dependence on the Protection-Window Thickness

Owing to their high photon detection efficiency, compactness, and low operating voltage, silicon photomultipliers (SiPMs) have found widespread application in many fields, including medical imaging, particle physics, and high-energy astrophysics. However, the so-called optical crosstalk (OCT) phenomenon of SiPMs is a major drawback to their adoption. Secondary infrared photons are emitted inside the silicon substrate spontaneously after the avalanche process caused by the primary incident photons, and they can be detected by the surrounding photodiodes. As a result large output pulses that are equivalent to multiple photoelectrons are observed with a certain probability (OCT rate), even for single-photon events, making the charge resolution worse and increasing the rate of accidental triggers by single-photon events in applications such as atmospheric Cherenkov telescopes. In our previous study, we found that the OCT rates of single-channel SiPMs was dependent on the thickness of their protection resin window, which may be explained by photon propagation inside the resin. In the present study, we measured the OCT rate of a multichannel SiPM and those of neighboring channels caused by photon propagation. Both OCT rates were found to be dependent on the protection-window thickness. We report our OCT measurements of a multichannel SiPM and comparisons with a ray-tracing simulation.

preprint2019arXiv

Development of a UV-transparent Lens Array for Enlarging the Effective Area of Multichannel SiPMs

We developed a UV-transparent lens array that can increase the photon detection efficiency of a silicon photomultiplier (SiPM) array comprising of 64 pixels ($3\times3$ mm$^2$ each) and 0.2-mm gaps. Through the plano-convex spherical lens on each $3.2\times3.2$ mm$^2$ region, we showed that the loss of photon detection efficiency due to the pixel gaps could be recovered as the incident photons get concentrated on the sensitive regions of the SiPM array. By using a prototype lens array, we achieved approximately 10%-30% relative increase in photon detection efficiency in our target angles of incidence of 30-60 deg.