Source author record

Adam Snyder

Adam Snyder appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2026arXiv

Report on LEO satellite impacts on ground-based optical astronomy for the Rubin Observatory LSST

In August 2025 a workshop was convened to bring together experts to better understand steps that can be taken to mitigate the impact of satellite constellations on astronomical observations. At the time, just over 12,000 operational satellites were in low-Earth orbit (LEO). Although reflected sunlight and emissions all across the electromagnetic spectrum from artificial satellites impact scientific observations and the sky, the workshop focused on reflected sunlight in the wavelength range 330 nm to 1100 nm. This aligns with the Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) planned imaging observations over the coming decade. Among other conclusions, we affirm previous recommendations that tracked satellite apparent magnitudes should be no brighter than 7th AB mag. The workshop participants discussed over 30 publications, reports, and presentations, and arrived at the Findings and Recommendations presented here. During the workshop, in addition to affirming many existing recommendations and best practices, the group discovered new issues and devised possible mitigations. These were nearly equally divided between advice to satellite builders and operators and to the observational astronomy community. While the workshop prioritized considerations for LSST, our hope is that many of the Findings and Recommendations will also apply to other observatories and constellations, and that all satellite companies will continue to engage in dialog with sky observers across the globe.

preprint2020arXiv

Investigation of Deferred Charge Effects in LSST ITL Sensors

The traditional characterization of charge transfer inefficiency (CTI) in charge-coupled devices (CCDs) can suffer from a number of deficiencies: CTI is often only calculated for a limited number of signal levels, CTI is calculated from a limited number of pixels, and the sources of CTI are usually assumed to occur at every pixel-to-pixel transfer. A number of serial CTI effects have been identified during preliminary testing of CCDs developed by Imaging Technology Laboratory (ITL) for use in the Large Synoptic Survey Telescope (LSST) camera focal plane that motivate additional study beyond the traditional CTI characterization. This study describes a more detailed examination of the serial deferred charge effects in order to fully characterize the deferred charge measured in the serial overscan pixels of these sensors. The results indicate that in addition to proportional CTI loss that occurs at each pixel transfer, ITL CCDs have additional contributions to the deferred charge measured in serial overscan pixels, likely caused by fixed CTI loss due to charge trapping, and an electronic offset drift at high signal.

preprint2014arXiv

Measurement of the absolute Quantum Efficiency of Hamamatsu model R11410-10 photomultiplier tubes at low temperatures down to liquid xenon boiling point

We report on the measurements of the absolute Quantum Efficiency(QE) for Hamamatsu model R11410-10 PMTs specially designed for the use in low background liquid xenon detectors. QE was measured for five PMTs in a spectral range between 154.5 nm to 400 nm at low temperatures down to -110$^0$C. It was shown that during the PMT cooldown from room temperature to -110 $^0$C (a typical PMT operation temperature in liquid xenon detectors), the absolute QE increases by a factor of 1.1 - 1.15 at 175 nm. The QE growth rate with respect to temperature is wavelength dependent peaking at about 165 nm corresponding to the fastest growth of about -0.07 %QE/$^{0}C$ and at about 200 nm corresponding to slowest growth of below -0.01 %QE/$^{0}C$. A dedicated setup and methods for PMT Quantum Efficiency measurement at low temperatures are described in details.