Researcher profile

Aaldert Elevelt

Aaldert Elevelt contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 11 - UnverifiedVerification L1Unclaimed author
1works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2019arXiv

Spiral Blurring Correction with Water-Fat Separation for Magnetic Resonance Fingerprinting in the Breast

PURPOSE: Magnetic Resonance Fingerprinting (MRF) with spiral readout enables rapid quantification of tissue relaxation times. However, it is prone to blurring due to off-resonance effects. Hence, fat blurring into adjacent regions might prevent identification of small tumors by their quantitative T1 and T2 values. This study aims to correct for the blurring artifacts, thereby enabling fast quantitative mapping in the female breast. METHODS: The impact of fat blurring on spiral MRF results was first assessed by simulations. Then, MRF was combined with 3-point Dixon water-fat separation and spiral blurring correction based on conjugate phase reconstruction. The approach was assessed in phantom experiments and compared to Cartesian reference measurements, namely inversion recovery (IR), multi-echo spin echo (MESE) and Cartesian MRF, by normalized root mean square error (NRMSE) and standard deviation (STD) calculations. Feasibility is further demonstrated in-vivo for quantitative breast measurements of 6 healthy female volunteers, age range 24-31 years. RESULTS: In the phantom experiment, the blurring correction reduced the NRMSE per phantom vial on average from 16% to 8% for T1 and from 18% to 11% for T2 when comparing spiral MRF to IR/MESE sequences. When comparing to Cartesian MRF, the NRMSE reduced from 15% to 8% for T1 and from 12% to 7% for T2. Furthermore, STDs decreased. In-vivo, the blurring correction removed fat bias on T1/T2 from a rim of about 7-8 mm width adjacent to fatty structures. CONCLUSION: The blurring correction for spiral MRF yields improved quantitative maps in the presence of water and fat.