Researcher profile

A. Zirizzotti

A. Zirizzotti contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
2topics
3close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2010arXiv

Design Of An Induction Probe For Simultaneous Measurements Of Permittivity And Resistivity

In this paper, we propose a discussion of the theoretical design and move towards the development and engineering of an induction probe for electrical spectroscopy which performs simultaneous and non invasive measurements on the electrical RESistivity ρand dielectric PERmittivity εr of non-saturated terrestrial ground and concretes (RESPER probe). In order to design a RESPER which measures ρand εr with inaccuracies below a prefixed limit (10%) in a band of low frequencies (LF) (B=100kHz), the probe should be connected to an appropriate analogical digital converter (ADC), which samples in uniform or in phase and quadrature (IQ) mode, otherwise to a lock-in amplifier. The paper develops only a suitable number of numerical simulations, using Mathcad, which provide the working frequencies, the electrode-electrode distance and the optimization of the height above ground minimizing the inaccuracies of the RESPER, in galvanic or capacitive contact with terrestrial soils or concretes, of low or high resistivity. As findings of simulations, we underline that the performances of a lock-in amplifier are preferable even when compared to an IQ sampling ADC with high resolution, under the same operating conditions. As consequences in the practical applications: if the probe is connected to a data acquisition system (DAS) as an uniform or an IQ sampler, then it could be commercialized for companies of building and road paving, being employable for analyzing "in situ" only concretes; otherwise, if the DAS is a lock-in amplifier, the marketing would be for companies of geophysical prospecting, involved to analyze "in situ" even terrestrial soils.

preprint2010arXiv

Optimal Requirements of a Data Acquisition System for a Quadrupolar Probe Employed in Electrical Spectroscopy

This paper discusses the development and engineering of electrical spectroscopy for simultaneous and non invasive measurement of electrical resistivity and dielectric permittivity. A suitable quadrupolar probe is able to perform measurements on a subsurface with inaccuracies below a fixed limit (10%) in a bandwidth of low (LF) frequency (100kHz). The quadrupole probe should be connected to an appropriate analogical digital converter (ADC) which samples in phase and quadrature (IQ) or in uniform mode. If the quadrupole is characterized by a galvanic contact with the surface, the inaccuracies in the measurement of resistivity and permittivity, due to the IQ or uniform sampling ADC, are analytically expressed. A large number of numerical simulations proves that the performances of the probe depend on the selected sampler and that the IQ is better compared to the uniform mode under the same operating conditions, i.e. bit resolution and medium.

preprint2009arXiv

Inaccuracy Assessment for Simultaneous Measurements of Resistivity and Permittivity applying Sensitivity and Transfer Function Approaches

This paper proposes a theoretical modelling of the simultaneous and non invasive measurement of electrical resistivity and dielectric permittivity, using a quadrupole probe on a subjacent medium. A mathematical-physical model is applied on propagation of errors in the measurement of resistivity and permittivity based on the sensitivity functions tool. The findings are also compared to the results of the classical method of analysis in the frequency domain, which is useful for determining the behaviour of zero and pole frequencies in the linear time invariant (LTI) circuit of the quadrupole. The paper underlines that average values of electrical resistivity and dielectric permittivity may be used to estimate the complex impedance over various terrains and concretes, especially when they are characterized by low levels of water saturation (content) and analyzed within a bandwidth ranging only from low (LF) to middle (MF) frequencies. In order to meet the design specifications which ensure satisfactory performances of the probe (inaccuracy no more than 10%), the forecasts provided by the sensitivity functions approach are less stringent than those foreseen by the transfer functions method (in terms of both a larger band of frequency f and a wider measurable range of resistivity or permittivity).