Researcher profile

A. Zatserklyaniy

A. Zatserklyaniy contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - Baseline
3works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2020arXiv

Properties of HPK UFSD after neutron irradiation up to 6e15 n/cm2

In this paper we report results from a neutron irradiation campaign of Ultra-Fast Silicon Detectors (UFSD) with fluences of 1e14, 3e14, 6e14, 1e15, 3e15, 6e15 n/cm2. The UFSD used in this study are circular 50 micro-meter thick Low-Gain Avalanche Detectors (LGAD), with a 1.0 mm diameter active area. They have been produced by Hamamatsu Photonics (HPK), Japan, with pre-radiation internal gain in the range 10-100 depending on the bias voltage. The sensors were tested pre-irradiation and post-irradiation with minimum ionizing particle (MIPs) from a 90Sr based \b{eta}-source. The leakage current, internal gain and the timing resolution were measured as a function of bias voltage at -20C and -30C. The timing resolution was extracted from the time difference with a second calibrated UFSD in coincidence, using the constant fraction method for both. The dependence of the gain upon the irradiation fluence is consistent with the concept of acceptor removal and the gain decreases from about 80 pre-irradiation to 7 after a fluence of 6e15 n/cm2. Consequently, the timing resolution was found to deteriorate from 20 ps to 50 ps. The results indicate that the most accurate time resolution is obtained at a value of the constant fraction discriminator (CFD) threshold used to determine the time of arrival varying with fluence, from 10% pre-radiation to 60% at the highest fluence. Key changes to the pulse shape induced by irradiation, i.e. (i) a reduce sensitivity of the pulse shape on the initial non-uniform charge deposition, (ii) the shortening of the rise time and (iii) the reduced pulse height, were compared with the WF2 simulation program and found to be in agreement.

preprint2012arXiv

Quartz Cherenkov Counters for Fast Timing: QUARTIC

We have developed particle detectors based on fused silica (quartz) Cherenkov radiators read out with micro-channel plate photomultipliers (MCP-PMTs) or silicon photomultipliers (SiPMs) for high precision timing (Sigma(t) about 10-15 ps). One application is to measure the times of small angle protons from exclusive reactions, e.g. p + p - p + H + p, at the Large Hadron Collider, LHC. They may also be used to measure directional particle fluxes close to external or stored beams. The detectors have small areas (square cm), but need to be active very close (a few mm) to the intense LHC beam, and so must be radiation hard and nearly edgeless. We present results of tests of detectors with quartz bars inclined at the Cherenkov angle, and with bars in the form of an "L" (with a 90 degree corner). We also describe a possible design for a fast timing hodoscope with elements of a few square mm.