Source author record

A. Turner

A. Turner appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

9works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2022arXiv

An Estimator for Lensing Potential from Galaxy Number Counts

We derive an estimator for the lensing potential from galaxy number counts which contains a linear and a quadratic term. We show that this estimator has a much larger signal-to-noise ratio than the corresponding estimator from intensity mapping. This is due to the additional lensing term in the number count angular power spectrum which is present already at linear order. We estimate the signal-to-noise ratio for future photometric surveys. Particularly at high redshifts, $z\gtrsim 1.5$, the signal to noise ratio can become of order 30. Therefore, the number counts in photometric surveys would be an excellent means to measure tomographic lensing spectra.

preprint2022arXiv

Training and Upgrading Tokamak Power Plants with Remountable Superconducting Magnets

All high field superconductors producing magnetic fields above 12 T are brittle. Nevertheless, they will probably be the materials of choice in commercial tokamaks because the fusion power density in a tokamak scales as the fourth power of magnetic field. Here we propose using robust, ductile superconductors during the reactor commissioning phase in order to avoid brittle magnet failure while operational safety margins are being established. Here we use the PROCESS systems code to inform development strategy and to provide detailed capital-cost-minimised tokamak power plant designs. We propose building a 'demonstrator' tokamak with an electric power output of 100 MWe, a plasma fusion gain Qplasma = 17, a net gain Qnet = 1.3, a cost of electricity (COE) of \$ 1148 (2021 US) per MWh (at 75 % availability) and high temperature superconducting operational TF magnets producing 5.4 T on-axis and 12.5 T peak-field. It uses Nb-Ti training magnets and will cost about \$ 9.75 Bn (2021 US). An equivalent 500 MWe plant has a COE of \$ 608 per MW suggesting that large tokamaks may eventually dominate the commercial market. We consider a range of designs optimised for capital cost (as the reactors considered are pilot plants) consisting of both 100 MWe and 500 MWe plants with each of two approaches for the magnets: training and upgrading. With training magnets, the plant is cost-optimised for REBCO TF magnets. For a 100 MWe plant, the Nb-Ti training magnets typically produce 70 % peak field on the toroidal field coils compared to REBCO magnets, 65 % peak field on the central solenoid and cost approx. 10 % of the total machine cost. Training magnets could in principle be reused for each of say 10 subsequent (commercial) machines and hence at 1 % bring only marginal additional cost.

preprint2021arXiv

BICEP / Keck XV: The BICEP3 CMB Polarimeter and the First Three Year Data Set

We report on the design and performance of the BICEP3 instrument and its first three-year data set collected from 2016 to 2018. BICEP3 is a 52cm aperture, refracting telescope designed to observe the polarization of the cosmic microwave background (CMB) on degree angular scales at 95GHz. It started science observation at the South Pole in 2016 with 2400 antenna-coupled transition-edge sensor (TES) bolometers. The receiver first demonstrated new technologies such as large-diameter alumina optics, Zotefoam infrared filters, and flux-activated SQUIDs, allowing $\sim 10\times$ higher optical throughput compared to the Keck design. BICEP3 achieved instrument noise-equivalent temperatures of 9.2, 6.8 and 7.1$μ\text{K}_{\text{CMB}}\sqrt{\text{s}}$ and reached Stokes $Q$ and $U$ map depths of 5.9, 4.4 and 4.4$μ$K-arcmin in 2016, 2017 and 2018, respectively. The combined three-year data set achieved a polarization map depth of 2.8$μ$K-arcmin over an effective area of 585 square degrees, which is the deepest CMB polarization map made to date at 95GHz.

preprint2014arXiv

Nuclear analysis and shielding optimisation in support of the ITER In-Vessel Viewing System design

The In-Vessel Viewing System (IVVS) units proposed for ITER are deployed to perform in-vessel examination. During plasma operations, the IVVS is located beyond the vacuum vessel, with shielding blocks envisaged to protect components from neutron damage and reduce shutdown dose rate (SDR) levels. Analyses were conducted to determine the effectiveness of several shielding configurations. The neutron response of the system was assessed using global variance reduction techniques and a surface source, and shutdown dose rate calculations were undertaken using MCR2S. Unshielded, the absorbed dose to piezoelectric motors (PZT) was found to be below stable limits, however activation of the primary closure plate (PCP) was prohibitively high. A scenario with shielding blocks at probe level showed significantly reduced PCP contact dose rate, however still marginally exceeded port cell requirements. The addition of shielding blocks at the bioshield plug demonstrated PCP contact dose rates below project requirements. SDR levels in contact with the isolated IVVS cartridge were found to marginally exceed the hands-on maintenance limit. For engineering feasibility, shielding blocks at bioshield level are to be avoided, however the port cell SDR field requires further consideration. In addition, alternative low-activation steels are being considered for the IVVS cartridge.

preprint2013arXiv

Improving computational efficiency of Monte-Carlo simulations with variance reduction

CCFE perform Monte-Carlo transport simulations on large and complex tokamak models such as ITER. Such simulations are challenging since streaming and deep penetration effects are equally important. In order to make such simulations tractable, both variance reduction (VR) techniques and parallel computing are used. It has been found that the application of VR techniques in such models significantly reduces the efficiency of parallel computation due to 'long histories'. VR in MCNP can be accomplished using energy-dependent weight windows. The weight window represents an 'average behaviour' of particles, and large deviations in the arriving weight of a particle give rise to extreme amounts of splitting being performed and a long history. When running on parallel clusters, a long history can have a detrimental effect on the parallel efficiency - if one process is computing the long history, the other CPUs complete their batch of histories and wait idle. Furthermore some long histories have been found to be effectively intractable. To combat this effect, CCFE has developed an adaptation of MCNP which dynamically adjusts the WW where a large weight deviation is encountered. The method effectively 'de-optimises' the WW, reducing the VR performance but this is offset by a significant increase in parallel efficiency. Testing with a simple geometry has shown the method does not bias the result. This 'long history method' has enabled CCFE to significantly improve the performance of MCNP calculations for ITER on parallel clusters, and will be beneficial for any geometry combining streaming and deep penetration effects.

preprint2011arXiv

Design and performance of the Spider instrument

Here we describe the design and performance of the Spider instrument. Spider is a balloon-borne cosmic microwave background polarization imager that will map part of the sky at 90, 145, and 280 GHz with sub-degree resolution and high sensitivity. This paper discusses the general design principles of the instrument inserts, mechanical structures, optics, focal plane architecture, thermal architecture, and magnetic shielding of the TES sensors and SQUID multiplexer. We also describe the optical, noise, and magnetic shielding performance of the 145 GHz prototype instrument insert.

preprint2010arXiv

The Herschel-SPIRE instrument and its in-flight performance

The Spectral and Photometric Imaging Receiver (SPIRE), is the Herschel Space Observatory`s submillimetre camera and spectrometer. It contains a three-band imaging photometer operating at 250, 350 and 500 microns, and an imaging Fourier Transform Spectrometer (FTS) which covers simultaneously its whole operating range of 194-671 microns (447-1550 GHz). The SPIRE detectors are arrays of feedhorn-coupled bolometers cooled to 0.3 K. The photometer has a field of view of 4' x 8', observed simultaneously in the three spectral bands. Its main operating mode is scan-mapping, whereby the field of view is scanned across the sky to achieve full spatial sampling and to cover large areas if desired. The spectrometer has an approximately circular field of view with a diameter of 2.6'. The spectral resolution can be adjusted between 1.2 and 25 GHz by changing the stroke length of the FTS scan mirror. Its main operating mode involves a fixed telescope pointing with multiple scans of the FTS mirror to acquire spectral data. For extended source measurements, multiple position offsets are implemented by means of an internal beam steering mirror to achieve the desired spatial sampling and by rastering of the telescope pointing to map areas larger than the field of view. The SPIRE instrument consists of a cold focal plane unit located inside the Herschel cryostat and warm electronics units, located on the spacecraft Service Module, for instrument control and data handling. Science data are transmitted to Earth with no on-board data compression, and processed by automatic pipelines to produce calibrated science products. The in-flight performance of the instrument matches or exceeds predictions based on pre-launch testing and modelling: the photometer sensitivity is comparable to or slightly better than estimated pre-launch, and the spectrometer sensitivity is also better by a factor of 1.5-2.

preprint2003arXiv

The Autohumidification Polymer Electrolyte Membrane Fuel Cell

A PEM fuel cell was specially constructed to determine kinetics under conditions of well-defined gas phase composition and cell temperature. Steady state multiplicity was discovered in the autohumidification PEM fuel cell, resulting from a balance between water production and water removal. Ignition was observed in the PEM fuel cell for a critical water activity of about 0.1. Ignition is a consequence of the exponential increase of proton conductivity with water activity, which creates an autocatalytic feedback between the water production and the proton conduction. The steady state current in the ignited state decreases with increasing temperature between 50 to 105 deg C. At temperatures greater than 70 deg C five steady states were observed in the PEM fuel cell. The steady state performance has been followed with variable load resistance and hysteresis loops have been mapped. The dynamics of transitions between steady states are slow about 10^3 to 10^4 s. These slow dynamics are suggested to result from a coupling of mechanical and chemical properties of the membrane electrode assembly due to swelling of the membrane with water absorption.

preprint1998arXiv

The HST Key Project on the Extragalactic Distance Scale XIV. The Cepheids in NGC 1365

We report the detection of Cepheid variable stars in the barred spiral galaxy NGC 1365, located in the Fornax cluster, using the Hubble Space Telescope Wide Field and Planetary Camera 2. Twelve V (F555W) and four I (F814W) epochs of observation were obtained. The two photometry packages, ALLFRAME and DoPHOT, were separately used to obtain profile-fitting photometry of all the stars in the HST field. The search for Cepheid variable stars resulted in a sample of 52 variables, with periods between 14 and 60 days, in common with both datasets. ALLFRAME photometry and light curves of the Cepheids are presented. A subset of 34 Cepheids were selected on the basis of period, light curve shape, similar ALLFRAME and DoPHOT periods, color, and relative crowding, to fit the Cepheid period-luminosity relations in V and I for both ALLFRAME and DoPHOT. The measured distance modulus to NGC 1365 from the ALLFRAME photometry is 31.31 +/- 0.20 (random) +/- 0.18 (systematic) mag, corresponding to a distance of 18.3 +/- 1.7 (random) +/- 1.6 (systematic) Mpc. The reddening is measured to be E(V-I) = 0.16 +/- 0.08 mag. These values are in excellent agreement with those obtained using the DoPHOT photometry, namely a distance modulus of 31.26 +/- 0.10 mag, and a reddening of 0.15 +/- 0.10 mag (internal errors only).