Researcher profile

A. Staude

A. Staude contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2016arXiv

Construction and Test of MDT Chambers for the ATLAS Muon Spectrometer

The Monitored Drift Tube (MDT) chambers for the muon spectrometer of the AT- LAS detector at the Large Hadron Collider (LHC) consist of 3-4 layers of pressurized drift tubes on either side of a space frame carrying an optical monitoring system to correct for deformations. The full-scale prototype of a large MDT chamber has been constructed with methods suitable for large-scale production. X-ray measurements at CERN showed a positioning accuracy of the sense wires in the chamber of better than the required 20 ?microns (rms). The performance of the chamber was studied in a muon beam at CERN. Chamber production for ATLAS now has started.

preprint2016arXiv

Construction and Test of the Precision Drift Chambers for the ATLAS Muon Spectrometer

The Monitored Drift Tube (MDT) chambers for the muon spectrometer of the ATLAS detector at the Large Hadron Collider (LHC) consist of 3-4 layers of pressurised drift tubes on either side of a space frame carrying an optical deformation monitoring system. The chambers have to provide a track position resolution of 40 microns with a single-tube resolution of at least 80 microns and a sense wire positioning accu- racy of 20 ?microns (rms). The feasibility was demonstrated with the full-scale prototype of one of the largest MDT chambers with 432 drift tubes of 3.8 m length. For the ATLAS muon spectrometer, 88 chambers of this type have to be built. The first chamber has been completed with a wire positioning accuracy of 14 microns (rms).

preprint2016arXiv

Performance of the ATLAS Muon Drift-Tube Chambers at High Background Rates and in Magnetic Fields

The ATLAS muon spectrometer uses drift-tube chambers for precision tracking. The performance of these chambers in the presence of magnetic field and high radiation fluxes is studied in this article using test-beam data recorded in the Gamma Irradiation Facility at CERN. The measurements are compared to detailed predictions provided by the Garfield drift-chamber simulation programme.

preprint2016arXiv

Performance of the ATLAS Precision Muon Chambers under LHC Operating Conditions

For the muon spectrometer of the ATLAS detector at the large hadron collider (LHC), large drift chambers consisting of 6 to 8 layers of pressurized drift tubes are used for precision tracking covering an active area of 5000 m2 in the toroidal field of superconducting air core magnets. The chambers have to provide a spatial resolution of 41 microns with Ar:CO2 (93:7) gas mixture at an absolute pressure of 3 bar and gas gain of 2?104. The environment in which the chambers will be operated is characterized by high neutron and background with counting rates of up to 100 per square cm and second. The resolution and efficiency of a chamber from the serial production for ATLAS has been investigated in a 100 GeV muon beam at photon irradiation rates as expected during LHC operation. A silicon strip detector telescope was used as external reference in the beam. The spatial resolution of a chamber is degraded by 4 ?m at the highest background rate. The detection efficiency of the drift tubes is unchanged under irradiation. A tracking efficiency of 98% at the highest rates has been demonstrated.

preprint2016arXiv

Resolution and Efficiency of the ATLAS Muon Drift-Tube Chambers at High Background Rates

The resolution and efficiency of a precision drift-tube chamber for the ATLAS muon spectrometer with final read-out electronics was tested at the Gamma Irradiation Facility at CERN in a 100 GeV muon beam and at photon irradiation rates of up to 990 Hz/square cm which corresponds to twice the highest background rate expected in ATLAS. A silicon strip detector telescope was used as external reference in the beam. The pulse-height measurement of the read-out electronics was used to perform time-slewing corrections which lead to an improvement of the average drift-tube resolution from 104 microns to 82 microns without irradiation and from 128 microns to 108 microns at the maximum expected rate. The measured drift-tube efficiency agrees with the expectation from the dead time of the read-out electronics up to the maximum expected rate.

preprint2009arXiv

V405 Peg (RBS 1955): A Nearby, Low-Luminosity Cataclysmic Binary

(Abridged). The cataclysmic binary V405 Peg, originally discovered as ROSAT Bright Source (RBS) 1955 (= 1RXS J230949.6+213523), shows a strong contribution from a late-type secondary star in its optical spectrum, which led Schwope et al. to suggest it to be among the nearest cataclysmic binaries. We present extensive optical observations of V405 Peg. Time-series spectroscopy shows the orbital period, Porb, to be 0.1776469(7) d (= 4.2635 hr), or 5.629 cycle/d. We classify the secondary as M3 - M4.5. Astrometry with the MDM 2.4m telescope gives a parallax 7.2 +- 1.1 milli-arcsec, and a relative proper motion of 58 mas/yr. Our best estimate of the distance yields d = 149 (+26, -20) pc. The secondary stars's radial velocity has K2 = 92 +- 3 km/s, indicating a fairly low orbital inclination if the masses are typical. Extensive I-band time-series observations in the show the system varying between a minimum brightness level of I = 14.14 and states of enhanced activity about 0.2 mag brighter. While the low-state shows an ellipsoidal modulation, an additional photometric modulation appears in the high state, with 0.1 mag amplitude and period 220-280 min. The frequency of this modulation appears to be stable for a month or so, but no single period was consistently detected from one observing season to the next. We estimate the system luminosity by combining optical measurements with the archival X-ray spectrum. The implied mass accretion rate is orders of magnitudes below the predictions for the standard angular momentum loss above the period gap. The system may possibly belong to a largely undiscovered population of hibernating CVs.