Source author record

A. Picciotto

A. Picciotto appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

X-Ray Silicon Drift Detector-CMOS Front-End System with High Energy Resolution at Room Temperature

We present a spectroscopic system constituted by a Silicon Drift Detector (SDD) coupled to a CMOS charge sensitive preamplifier, named SIRIO, specifically designed to reach ultimate low noise levels. The SDD, with an active area of 13 mm , has been manufactured by optimizing the production processes in order to reduce the anode current, successfully reaching current densities between 17 pA/cm and 25 pA/cm at 20 for drift fields ranging from 100 V/cm to 500 V/cm. The preamplifier shows minimum intrinsic noise levels of 1.27 and 1.0 electrons r.m.s. at 20 and 30 , respectively. At room temperature ( ) the 5.9 keV and the pulser lines have 136 eV and 64 eV FWHM, respectively, corresponding to an equivalent noise charge of 7.4 electrons r.m.s.; the noise threshold is at 165 eV. The energy resolution, as measured on the pulser line, ranges from 82 eV FWHM (9.4 electrons r.m.s.) at 30C down to 29 eV FWHM (3.3 electrons r.m.s.) at 30C .

preprint2021arXiv

An innovative architecture for a wide band transient monitor on board the HERMES nano-satellite constellation

The HERMES-TP/SP mission, based on a nanosatellite constellation, has very stringent constraints of sensitivity and compactness, and requires an innovative wide energy range instrument. The instrument technology is based on the "siswich" concept, in which custom-designed, low-noise Silicon Drift Detectors are used to simultaneously detect soft X-rays and to readout the optical light produced by the interaction of higher energy photons in GAGG:Ce scintillators. To preserve the inherent excellent spectroscopic performances of SDDs, advanced readout electronics is necessary. In this paper, the HERMES detector architecture concept will be described in detail, as well as the specifically developed front-end ASICs (LYRA-FE and LYRA-BE) and integration solutions. The experimental performance of the integrated system composed by scintillator+SDD+LYRA ASIC will be discussed, demonstrating that the requirements of a wide energy range sensitivity, from 2 keV up to 2 MeV, are met in a compact instrument.

preprint2016arXiv

Avalanche boron fusion by laser picosecond block ignition with magnetic trapping for clean and economic reactor

After the very long consideration of the ideal energy source by fusion of the protons of light hydrogen with the boron isotope 11 (boron fusion HB11) the very first two independent measurements of very high reaction gains by lasers basically opens a fundamental breakthrough. The non-thermal plasma block ignition with extremely high power laser pulses above petawatt of picosecond duration in combination with up to ten kilotesla magnetic fields for trapping has to be combined to use the measured high gains as proof of an avalanche reaction for an environmentally clean, low cost and lasting energy source as potential option against global warming. The unique HB11 avalanche reaction is are now based on elastic collisions of helium nuclei (alpha particles) limited only to a reactor for controlled fusion energy during a very short time within a very small volume.

preprint2016arXiv

eXTP -- enhanced X-ray Timing and Polarimetry Mission

eXTP is a science mission designed to study the state of matter under extreme conditions of density, gravity and magnetism. Primary targets include isolated and binary neutron stars, strong magnetic field systems like magnetars, and stellar-mass and supermassive black holes. The mission carries a unique and unprecedented suite of state-of-the-art scientific instruments enabling for the first time ever the simultaneous spectral-timing-polarimetry studies of cosmic sources in the energy range from 0.5-30 keV (and beyond). Key elements of the payload are: the Spectroscopic Focusing Array (SFA) - a set of 11 X-ray optics for a total effective area of about 0.9 m^2 and 0.6 m^2 at 2 keV and 6 keV respectively, equipped with Silicon Drift Detectors offering <180 eV spectral resolution; the Large Area Detector (LAD) - a deployable set of 640 Silicon Drift Detectors, for a total effective area of about 3.4 m^2, between 6 and 10 keV, and spectral resolution <250 eV; the Polarimetry Focusing Array (PFA) - a set of 2 X-ray telescope, for a total effective area of 250 cm^2 at 2 keV, equipped with imaging gas pixel photoelectric polarimeters; the Wide Field Monitor (WFM) - a set of 3 coded mask wide field units, equipped with position-sensitive Silicon Drift Detectors, each covering a 90 degrees x 90 degrees FoV. The eXTP international consortium includes mostly major institutions of the Chinese Academy of Sciences and Universities in China, as well as major institutions in several European countries and the United States. The predecessor of eXTP, the XTP mission concept, has been selected and funded as one of the so-called background missions in the Strategic Priority Space Science Program of the Chinese Academy of Sciences since 2011. The strong European participation has significantly enhanced the scientific capabilities of eXTP. The planned launch date of the mission is earlier than 2025.

preprint2016arXiv

Prompt gamma ray diagnostics and enhanced hadron-therapy using neutron-free nuclear reactions

We propose a series of simulations about the potential use of Boron isotopes to trigger neutron-free (aneutronic) nuclear reactions in cancer cells through the interaction with an incoming energetic proton beam, thus resulting in the emission of characteristic prompt gamma radiation (429 keV, 718 keV and 1435 keV). Furthermore assuming that the Boron isotopes are absorbed in cancer cells, the three alpha-particles produced in each p-11B aneutronic nuclear fusion reactions can potentially result in the enhancement of the biological dose absorbed in the tumor region since these multi-MeV alpha-particles are stopped inside the single cancer cell, thus allowing to spare the surrounding tissues. Although a similar approach based on the use of 11B nuclei has been proposed in [1], our work demonstrate, using Monte Carlo simulations, the crucial importance of the use of 10B nuclei (in a solution containing also 11B) for the generation of prompt gamma-rays, which can be applied to medical imaging. In fact, we demonstrate that the use of 10B nuclei can enhance the intensity of the 718 keV gamma-ray peak more than 30 times compared to the solution containing only 11B nuclei. A detailed explanation of the origin of the different prompt gamma-rays, as well as of their application as real-time diagnostics during a potential cancer treatment, is here discussed.

preprint2014arXiv

Characterization of the VEGA ASIC coupled to large area position-sensitive Silicon Drift Detectors

Low-noise, position-sensitive Silicon Drift Detectors (SDDs) are particularly useful for experiments in which a good energy resolution combined with a large sensitive area is required, as in the case of X-ray astronomy space missions and medical applications. This paper presents the experimental characterization of VEGA, a custom Application Specific Integrated Circuit (ASIC) used as the front-end electronics for XDXL-2, a large-area (30.5 cm^2) SDD prototype. The ASICs were integrated on a specifically developed PCB hosting also the detector. Results on the ASIC noise performances, both stand-alone and bonded to the large area SDD, are presented and discussed.