Researcher profile

A. Pandey

A. Pandey contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

Heat radiation reduction in the cryostat with multilayer insulation technique

Multilayer insulation (MLI) is an important technique for the reduction of radiation heat load in cryostats. The present work is focused on investigation for the selection of suitable reflective layer and spacer material in MLI systems. In our analysis, we have selected perforated double-Aluminized Mylar (DAM) with Dacron, unperforated DAM with Silk-net and perforated DAM with Glass-tissue for their evaluation as the reflective layer as well as spacer materials in MLI technique. Current work would discuss the calculation of the effect of layer density and the number of layers on the heat load. Knowing the key parameters of MLI, we have compared the heat load generation in spherical as well as cylindrical cryostats and the effect of layering near and outer surface on the heat load.

preprint2020arXiv

Interaction potentials and ultracold scattering cross sections for the $^7$Li$^+$-$^7$Li ion-atom system

We calculate the isotope independent Li$^+$-Li potential energy curves for the electronic ground and first excited states. Scattering phase shifts and total scattering cross section for the $^7$Li$^+$-$^7$Li collision are calculated with emphasis on the ultra-low energy domain down to the $s$-wave regime. The effect of physically motivated alterations on the calculated potential energy curves is used to determine the bound of accuracy of the low-energy scattering parameters for the ion-atom system. It is found that the scattering length for the A$^2Σ_u^+$ state, $a_u$ = 1325 a$_0$, is positive and has well-constrained bounds. For the X$^2Σ_g^+$ state, the scattering length, $a_g$ = 20465 a$_0$ has a large magnitude as it is sensitive to the restrained change of the potential, due to the presence of a vibrational state in the vicinity of the dissociation limit.

preprint2019arXiv

Full orbital solution for the binary system in the northern Galactic disc microlensing event Gaia16aye

Gaia16aye was a binary microlensing event discovered in the direction towards the northern Galactic disc and was one of the first microlensing events detected and alerted to by the Gaia space mission. Its light curve exhibited five distinct brightening episodes, reaching up to I=12 mag, and it was covered in great detail with almost 25,000 data points gathered by a network of telescopes. We present the photometric and spectroscopic follow-up covering 500 days of the event evolution. We employed a full Keplerian binary orbit microlensing model combined with the motion of Earth and Gaia around the Sun to reproduce the complex light curve. The photometric data allowed us to solve the microlensing event entirely and to derive the complete and unique set of orbital parameters of the binary lensing system. We also report on the detection of the first-ever microlensing space-parallax between the Earth and Gaia located at L2. The properties of the binary system were derived from microlensing parameters, and we found that the system is composed of two main-sequence stars with masses 0.57$\pm$0.05 $M_\odot$ and 0.36$\pm$0.03 $M_\odot$ at 780 pc, with an orbital period of 2.88 years and an eccentricity of 0.30. We also predict the astrometric microlensing signal for this binary lens as it will be seen by Gaia as well as the radial velocity curve for the binary system. Events such as Gaia16aye indicate the potential for the microlensing method of probing the mass function of dark objects, including black holes, in directions other than that of the Galactic bulge. This case also emphasises the importance of long-term time-domain coordinated observations that can be made with a network of heterogeneous telescopes.

preprint2018arXiv

Characteristic Study and Development of Surface Resistivity Measuring Device for Resistive Plate Chamber Detector

The India-based Neutrino Observatory (INO) is an approved multi-institutional experiment of India. It will use maximum 30,000 Resistive Plate Chamber (RPC) of size 2x2m as an active detector in which each will be sandwiched between two iron plates. Each RPC detectors will be made up of 3mm thick glass (or Bakelite) plates whose one surface will be coated with graphite paint to work as electrode. To achieve effective and uniform electric field, the coated graphite paint must have uniform distribution over the glass surface. Uniformity can be demonstrated by measuring the surface resistance of the coated graphite paint. However, manual measurement of 60,000 electrodes with the help of multimeter and the jig demands huge amount of person-hour with compromised accuracy, and therefore that requires the need and importance of the automatic scanning system. An advanced automatic scanning system (ASS) has been designed & developed to fulfill the required needs and overcome the shortcomings of the initially developed system. Measurement are sensitive to the contact pressure between the jig and RPC electrode's surface. In this paper, various parameters of the ASS have been precisely fixed. Obtained results are compared with the standard one and found satisfactory within error. It has been observed that for obtaining the correct and safe value of surface resistance, applied pressure value in terms of force should be in the range of 9-11 Newton.