Source author record

A. P. Chubenko

A. P. Chubenko appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2019arXiv

New complex EAS installation of the Tien Shan Mountain Cosmic Ray Station

We present a description of the new complex installation for the study of extensive air showers which was created at the Tien Shan mountain cosmic ray station, as well as the results of the test measurements made there in 2014-2016. At present, the system for registration of electromagnetic shower component consists of $\sim$100 detector points built on the basis of plastic scintillator plates with the sensitive area of 0.25m$^2$ and 1m$^2$, spread equidistantly over $\sim$10$^4$m$^2$ space. The dynamic range of scintillation amplitude measurements is currently about $(3-7)\cdot 10^4$, and there is a prospect of it being extended up to $\sim$10$^6$. The direction of shower arrival is defined by signal delays from a number of the scintillators placed cross-wise at the periphery of the detector system. For the investigation of nuclear active shower components there was created a multi-tier 55m$^2$ ionization-neutron calorimeter with a sum absorber thickness of $\sim$1000g/cm$^2$, typical spatial resolution of the order of 10cm, and dynamic range of ionization measurement channel about $\sim$10$^5$. Also, the use of saturation-free neutron detectors is anticipated for registration of the high- and low-energy hadron components in the region of shower core. A complex of underground detectors is designed for the study of muonic and penetrative nuclear-active components of the shower. The full stack of data acquisition, detector calibration, and shower parameters restoration procedures are now completed, and the newly obtained shower size spectrum and lateral distribution of shower particles occur in agreement with conventional data. Future studies in the field of $10^{14}-10^{17}$eV cosmic ray physics to be held at the new shower installation are discussed.

preprint2016arXiv

About the possible signature of pion bose condensation contribution in the high energy cosmic ray nuclear interactions

The events of anomalous energy deposit and high number of hadrons in hadron calorimeter, often not accompanied at all, or accompanied by very small EAS of cosmic rays, are observed by means of the complex installation aimed at research of cosmic rays. The data quoted and their analysis point to the real contribution and the essential role of pion Bose condensation in high energy nuclear interactions. The possibility of the existence of such process in the nuclear matter (in the neutron stars and in some kinds of the nuclei) was proposed by A.B.Migdal in 1971.

preprint2014arXiv

Channeling Effect in Polycrystalline Deuterium-Saturated CVD Diamond Target Bombarded by Deuterium Ion Beam

At the ion accelerator HELIS at the LPI, the neutron yield is investigated in DD reactions within a polycrystalline deuterium-saturated CVD diamond, during an irradiation of its surface by a deuterium ion beam with the energy less than 30 keV. The measurements of the neutron flux in the beam direction are performed in dependence on the target angle, \b{eta}, with respect to the beam axis. These measurements are performed using a multichannel detector based on He3 counters. A significant anisotropy in neutron yield is observed, it was higher by a factor of 3 at \b{eta}=0 compared to that at \b{eta} = +-45°. The possible reasons for the anisotropy, including ion channeling, are discussed.

preprint2013arXiv

Observation of the prior earthquake effect on the flux of environmental neutrons, gamma-radiation, and on the local electric field in Tien Shan mountain

A search for the possible precursors of an earthquake and its effect on the data series of diverse geophysical parameters has been made in the mountain of Northern Tien Shan. The complex installation included the NM64 type neutron supermonitor, detectors of the environmental low-energy neutrons, the scintillation gamma-detector, the sensor of the local electric field, a seismograph, and a weather-station. The specialized data filtration methodic was elaborated with an enhanced sensitivity to the transient signals of seismic origin. On the eve of, and after a 5.4 magnitude earthquake the fine features in temporal behavior of the intensity of low-energy neutron and gamma-radiation background, so as irregularities of the local electric field were observed which seem to be in a close correlation with each other. These results may be an evidence of the possibility of experimental identification of earthquake's precursors in the time up to 2-3 days before the beginning of a period of intensive tectonic activity.

preprint2013arXiv

Registration of the signal of a star and PCR sources optical radiation by means of the installation, aimed at the investigation of EAS of high energy cosmic rays

With the help of the experimental installation aimed at the investigation of high energy cosmic rays (Tien-Shan high mountain laboratory) the signal of Solar and star optical radiation is registered. The signal is well provided statistically and possesses the strictly expressed maximum in the region of EAS sizes Ne 1.19 106 particles (primary energy Eo 1.33 1015 eV). This signal is the peak from gamma EAS, generated by gamma quanta from decay of pi zero mesons, photo produced by the Primary Cosmic Radiation (PCR) nuclei on the photons of stars and of PCR sources. The assumption is made, that exactly this process provides the main contribution in the formation of so called knee on the primary spectrum. Due to the universality and distinct maximum of this signal, its usage for independent and reliable calibration of the EAS installations, for the mutual calibration of these installations and, possibly, for the merger of experimental data obtained by means of these installations to increase the statistics, is proposed. It is especially vital to day, when the further essential increase of the energy range under investigation is necessary.