Source author record

A. Okamura

A. Okamura appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Precision measurement of a brown dwarf mass in a binary system in the microlensing event OGLE-2019-BLG-0033/MOA-2019-BLG-035

Context. Brown dwarfs are poorly understood transition objects between stars and planets, with several competing mechanisms having been proposed for their formation. Mass measurements are generally difficult for isolated objects but also for brown dwarfs orbiting low-mass stars, which are often too faint for spectroscopic follow-up. Aims. Microlensing provides an alternative tool for the discovery and investigation of such faint systems. Here we present the analysis of the microlensing event OGLE-2019-BLG-0033/MOA-2019-BLG-035, which is due to a binary system composed of a brown dwarf orbiting a red dwarf. Methods. Thanks to extensive ground observations and the availability of space observations from Spitzer, it has been possible to obtain accurate estimates of all microlensing parameters, including parallax, source radius and orbital motion of the binary lens. Results. After accurate modeling, we find that the lens is composed of a red dwarf with mass $M_1 = 0.149 \pm 0.010M_\odot$ and a brown dwarf with mass $M_2 = 0.0463 \pm 0.0031M_\odot$, at a projected separation of $a_\perp = 0.585$ au. The system has a peculiar velocity that is typical of old metal-poor populations in the thick disk. Percent precision in the mass measurement of brown dwarfs has been achieved only in a few microlensing events up to now, but will likely become common with the Roman space telescope.

preprint2014arXiv

Effects of radiation damage caused by proton irradiation on Multi-Pixel Photon Counters (MPPCs)

We have investigated the effects caused by proton-induced radiation damage on Multi-Pixel Photon Counter (MPPC), a pixelized photon detector developed by Hamamatsu Photonics. The leakage current of irradiated MPPC samples linearly increases with total irradiated doses due to radiation damage, which is not completely recovered even after a year from the irradiation. No significant change has been observed in the gains at least up to 8.0 Gy ($9.1\times10^7$ n/mm$^2$ in 1 MeV neutron equivalent fluence, $Φ_{\rm eq}$). The device has completely lost its photon-counting capability due to baseline fluctuations and noise pile-up after 21 Gy irradiation ($2.4\times10^8$ n/mm$^2$ in $Φ_{\rm eq}$), which might be problematic for some applications, such as ring-imaging Cherenkov detectors. We have found that the pulse-height resolution has been slightly deteriorated after 42 Gy irradiation ($4.8\times10^8$ n/mm$^2$ in $Φ_{\rm eq}$), where the measured sample has been illuminated with a few hundred photons. This effect should be considered in the case of energy-measurement applications.

preprint2013arXiv

Hypernuclear spectroscopy of products from 6Li projectiles on a carbon target at 2 AGeV

A novel experiment, aiming at demonstrating the feasibility of hypernuclear spectroscopy with heavy-ion beams, was conducted. Using the invariant mass method, the spectroscopy of hypernuclear products of 6Li projectiles on a carbon target at 2 AGeV was performed. Signals of the Λ-hyperon and 3ΛH and 4ΛH hypernuclei were observed for final states of p+π^-, 3He+π^- and 4He+π^-, respectively, with significance values of 6.7, 4.7 and 4.9σ. By analyzing the proper decay time from secondary vertex distribution with the unbinned maximum likelihood fitting method, their lifetime values were deduced to be $262 ^{+56}_{-43} \pm 45$ ps for Λ, $183 ^{+42}_{-32} \pm 37$ ps for 3ΛH, and $140 ^{+48}_{-33}\pm 35 $ ps for 4ΛH.