Source author record

A. Mavalankar

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

3works
4topics
4close collaborators

Published work

3 publications

preprint2020arXiv

Radio-frequency reflectometry of a quantum dot using an ultra-low-noise SQUID amplifier

Fault-tolerant spin-based quantum computers will require fast and accurate qubit readout. This can be achieved using radio-frequency reflectometry given sufficient sensitivity to the change in quantum capacitance associated with the qubit states. Here, we demonstrate a 23-fold improvement in capacitance sensitivity by supplementing a cryogenic semiconductor amplifier with a SQUID preamplifier. The SQUID amplifier operates at a frequency near 200 MHz and achieves a noise temperature below 600 mK when integrated into a reflectometry circuit, which is within a factor 120 of the quantum limit. It enables a record sensitivity to capacitance of 0.07 aF/\sqrt{Hz}. The setup is used to acquire charge stability diagrams of a gate-defined double quantum dot in a short time with a signal-to-noise ration of about 38 in 1 microsecond of integration time.

preprint2015arXiv

Sensitive radio-frequency measurements of a quantum dot by tuning to perfect impedance matching

Electrical readout of spin qubits requires fast and sensitive measurements, but these are hindered by poor impedance matching to the device. We demonstrate perfect impedance matching in a radio-frequency readout circuit, realized by incorporating voltage-tunable varactors to cancel out parasitic capacitances. In the optimized setup, a capacitance sensitivity of 1.6 aF/Hz1.6~\mathrm{aF}/\sqrt{\mathrm{Hz}} is achieved at a maximum source-drain bias of 170 μ170~μV root-mean-square and with bandwidth above 15 15~MHz. Coulomb blockade is measured via both conductance and capacitance in a quantum dot, and the two contributions are found to be proportional, as expected from a quasistatic tunneling model. We benchmark our results against the requirements for single-shot qubit readout using quantum capacitance, a goal that has so far been elusive.

preprint2013arXiv

A non-invasive electron thermometer based on charge sensing of a quantum dot

We present a thermometry scheme to extract the temperature of a 2DEG by monitoring the charge occupation of a weakly tunnel-coupled 'thermometer' quantum dot using a quantum point contact detector. Electronic temperatures between 97 mK and 307 mK are measured by this method with an accuracy of up to 3 mK, and agree with those obtained by measuring transport through a quantum dot. The thermometer does not pass a current through the 2DEG, and can be incorporated as an add-on to measure the temperature simultaneously with another operating device. Further, the tuning is independent of temperature.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.