Researcher profile

A. M. Levine

A. M. Levine contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2010arXiv

What ignites on the neutron star of 4U 0614+091?

[abridged] The LMXB 4U 0614+091 is a source of sporadic thermonuclear (type I) X-ray bursts. We find bursts with a wide variety of characteristics in serendipitous wide-field X-ray observations by EURECA/WATCH, RXTE/ASM, BeppoSAX/WFC, HETE-2/FREGATE, INTEGRAL/IBIS/ISGRI, and Swift/BAT, as well as pointed observations by RXTE/PCA and HEXTE. Most of them reach a peak flux of ~15 Crab, but a few only reach a peak flux below a Crab. One of the bursts shows a very strong photospheric radius-expansion phase. This allows us to evaluate the distance to the source: 3.2 kpc. The burst durations are between 10 sec to 5 min. However, after one of the intermediate-duration bursts, a faint tail is seen to at least ~2.4 hours after the start of the burst. One very long burst lasted for several hours. This superburst candidate was followed by a normal type-I burst only 19 days later. This is, to our knowledge, the shortest burst-quench time among the superbursters. A superburst in this system is difficult to reconcile if it accretes at ~1% L_Edd. The intermediate-duration bursts occurred when 4U 0614+091's persistent emission was lowest and calm, and when bursts were infrequent (on average one every month to 3 months). The average burst rate increased significantly after this period. The maximum average burst recurrence rate is once every week to 2 weeks. The burst behaviour may be partly understood if there is at least an appreciable amount of helium present in the accreted material from the donor star. If the system is an ultra-compact X-ray binary with a CO white-dwarf donor, as has been suggested, this is unexpected. If the bursts are powered by helium, we find that the energy production per accumulated mass is about 2.5 times less than expected for pure helium matter.

preprint2009arXiv

Monitoring campaign of 1RXS J171824.2-402934, the low-mass X-ray binary with the lowest mass accretion rate

An X-ray monitoring campaign with Chandra and Swift confirms that 1RXS J171824.2-402934 is accreting at the lowest rate among the known persistently accreting low-mass X-ray binaries. A thermonuclear X-ray burst was detected with the all-sky monitor on RXTE. This is only the second such burst seen in 1RXS J171824.2-402934 in more than 20 Ms of observations done over 19 years. The low burst recurrence rate is in line with the low accretion rate. The persistent nature and low accretion rate can be reconciled within accretion disk theory if the binary system is ultracompact. An unprecedentedly short orbital period of less than approximately 7 minutes would be implied. An ultracompact nature, together with the properties of the type I X-ray burst, suggests, in turn, that helium-rich material is accreted. Optical follow-up of the Chandra error region does not reveal an unambiguous counterpart.

preprint2007arXiv

Lost and Found: A New Position and Infrared Counterpart for the X-ray Binary Scutum X-1

Using archival X-ray data, we find that the catalog location of the X-ray binary Scutum X-1 (Sct X-1) is incorrect, and that the correct location is that of the X-ray source AX J183528-0737, which is 15' to the west. Our identification is made on the basis of the 112-s pulse period for this object detected in an XMM-Newton observation, as well as spatial coincidence between AX J183528-0737 and previous X-ray observations. Based on the XMM-Newton data and archival RXTE data, we confirm secular spin-down over 17 years with period derivative Pdot~3.9e-9 s/s, but do not detect a previously reported X-ray iron fluorescence line. We identify a bright (Ks=6.55), red (J-Ks=5.51), optical and infrared counterpart to AX J183528-0737 from 2MASS, a number of mid-IR surveys, and deep optical observations, which we use to constrain the extinction to and distance of Sct X-1. From these data, as well as limited near-IR spectroscopy, we conclude that Sct X-1 is most likely a binary system comprised of a late-type giant or supergiant and a neutron star.

preprint2001arXiv

Use of Gas Electron Multiplier (GEM) Detectors for an Advanced X-ray Monitor

We describe a concept for a NASA SMEX Mission in which Gas Electron Multiplier (GEM) detectors, developed at CERN, are adapted for use in X-ray astronomy. These detectors can be used to obtain moderately large detector area and two-dimensional photon positions with sub mm accuracy in the range of 1.5 to 15 keV. We describe an application of GEMs with xenon gas, coded mask cameras, and simple circuits for measuring event positions and for anticoincidence rejection of particle events. The cameras are arranged to cover most of the celestial sphere, providing high sensitivity and throughput for a wide variety of cosmic explosions. At longer timescales, persistent X-ray sources would be monitored with unprecedented levels of coverage. The sensitivity to faint X-ray sources on a one-day timescale would be improved by a factor of 6 over the capability of the RXTE All Sky Monitor.

preprint1999arXiv

The X-ray, Optical and Infrared Counterpart to GRB 980703

We report on X-ray, optical and infrared follow-up observations of GRB 980703. We detect a previously unknown X-ray source in the GRB error box; assuming a power law decline we find for its decay index alpha < -0.91 (3-sigma). We invoke host galaxy extinction to match the observed spectral slope with the slope expected from `fireball&#39; models. We find no evidence for a spectral break in the infrared to X-ray spectral range on 1998 July 4.4, and determine a lower limit of the cooling break frequency: nu_c > 1.3 x 10^{17} Hz. For this epoch we obtain an extinction of A_V = 1.50 +/- 0.11. From the X-ray data we estimate the optical extinction to be A_V = 20.2 +12.3 -7.3, inconsistent with the former value. Our optical spectra confirm the redshift of z = 0.966 found by Djorgovski et al. (1998). We compare the afterglow of GRB 980703 with that of GRB 970508 and find that the fraction of the energy in the magnetic field, epsilon_B < 6x10^{-5}, is much lower in the case of GRB 980703, which is a consequence of the high frequency of the cooling break.

preprint1996arXiv

Quantum Versus Mean Field Behavior of Normal Modes of a Bose-Einstein Condensate in a Magnetic Trap

Quantum evolution of a collective mode of a Bose-Einstein condensate containing a finite number N of particles shows the phenomena of collapses and revivals. The characteristic collapse time depends on the scattering length, the initial amplitude of the mode and N. The corresponding time values have been derived analytically under certain approximation and numerically for the parabolic atomic trap. The revival of the mode at time of several seconds, as a direct evidence of the effect, can occur, if the normal component is significantly suppressed. We also discuss alternative means to verify the proposed mechanism.