Source author record

A. Lobo

A. Lobo appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2016arXiv

Interpolation of the magnetic field at the test masses in eLISA

A feasible design for a magnetic diagnostics subsystem for eLISA will be based on that of its precursor mission, LISA Pathfinder. Previous experience indicates that magnetic field estimation at the positions of the test masses has certain complications. This is due to two reasons. The first one is that magnetometers usually back-act due to their measurement principles (i.e., they also create their own magnetic fields), while the second is that the sensors selected for LISA Pathfinder have a large size, which conflicts with space resolution and with the possibility of having a sufficient number of them to properly map the magnetic field around the test masses. However, high-sensitivity and small-size sensors that significantly mitigate the two aforementioned limitations exist, and have been proposed to overcome these problems. Thus, these sensors will be likely selected for the magnetic diagnostics subsystem of eLISA. Here we perform a quantitative analysis of the new magnetic subsystem, as it is currently conceived, and assess the feasibility of selecting these sensors in the final configuration of the magnetic diagnostic subsystem.

preprint2016arXiv

Low-frequency noise characterization of a magnetic field monitoring system using an anisotropic magnetoresistance

A detailed study about magnetic sensing techniques based on anisotropic magnetoresistive sensors shows that the technology is suitable for low-frequency space applications like the eLISA mission. Low noise magnetic measurements at the sub-millihertz frequencies were taken by using different electronic noise reduction techniques in the signal conditioning circuit. We found that conventional modulation techniques reversing the sensor bridge excitation do not reduce the potential $1/f$ noise of the magnetoresistors, so alternative methods such as flipping and electro-magnetic feedback are necessary. In addition, a low-frequency noise analysis of the signal conditioning circuits has been performed in order to identify and minimize the different main contributions from the overall noise. The results for chip-scale magnetoresistances exhibit similar noise along the eLISA bandwidth ($0.1\,{\rm mHz}-1\,{\rm Hz}$) to the noise measured by means of the voluminous fluxgate magnetometers used in its precursor mission, known as LISA Pathfinder.

preprint2009arXiv

ADC non-linear errors correction in thermal diagnostics for the LISA mission

Low-noise temperature measurements at frequencies in the milli-Hertz range are needed in the LISA and LISA PathFinder (LPF). The required temperature stability for LISA is around 10 uK/sqrt(Hz) at frequencies down to 0.1 mHz. In this paper we focus on the identification and reduction of a source of excess noise detected when measuring time-varying temperature signals. This is shown to be due to non-idealities in the ADC transfer curve, and degrades the measurement by about one order of magnitude in the measurement bandwidth when the measured temperature exhibits drifts of uK/s. In a suitable measuring system for the LISA mission, this noise needs to be reduced. Two different methods based on the same technique have been implemented, both consisting in the addition of dither signals out of band to mitigate the ADC non-ideality errors. Excess noise of this nature has been satisfactorily reduced by using these methods when measuring temperature ramps up to 10 uK/s .