Source author record

A. Hrnjic

A. Hrnjic appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2020arXiv

Laser Calibration System for Time of Flight Scintillator Arrays

A laser calibration system was developed for monitoring and calibrating time of flight (TOF) scintillating detector arrays. The system includes setups for both small- and large-scale scintillator arrays. Following test-bench characterization, the laser system was recently commissioned in experimental Hall B at the Thomas Jefferson National Accelerator Facility for use on the new Backward Angle Neutron Detector (BAND) scintillator array. The system successfully provided time walk corrections, absolute time calibration, and TOF drift correction for the scintillators in BAND. This showcases the general applicability of the system for use on high-precision TOF detectors.

preprint2020arXiv

The CLAS12 Backward Angle Neutron Detector (BAND)

The Backward Angle Neutron Detector (BAND) of CLAS12 detects neutrons emitted at backward angles of $155^\circ$ to $175^\circ$, with momenta between $200$ and $600$ MeV/c. It is positioned 3 meters upstream of the target, consists of $18$ rows and $5$ layers of $7.2$ cm by $7.2$ cm scintillator bars, and read out on both ends by PMTs to measure time and energy deposition in the scintillator layers. Between the target and BAND there is a 2 cm thick lead wall followed by a 2 cm veto layer to suppress gammas and reject charged particles. This paper discusses the component-selection tests and the detector assembly. Timing calibrations (including offsets and time-walk) were performed using a novel pulsed-laser calibration system, resulting in time resolutions better than $250$ ps (150 ps) for energy depositions above 2 MeVee (5 MeVee). Cosmic rays and a variety of radioactive sources were used to calibration the energy response of the detector. Scintillator bar attenuation lengths were measured. The time resolution results in a neutron momentum reconstruction resolution, $δp/p < 1.5$\% for neutron momentum $200\le p\le 600$ MeV/c. Final performance of the BAND with CLAS12 is shown, including electron-neutral particle timing spectra and a discussion of the off-time neutral contamination as a function of energy deposition threshold.