Researcher profile

A. Gros

A. Gros contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2013arXiv

In-flight calibration of the INTEGRAL/IBIS mask

Since the release of the INTEGRAL Offline Scientific Analysis (OSA) software version 9.0, the ghost busters module has been introduced in the INTEGRAL/IBIS imaging procedure, leading to an improvement of the sensitivity around bright sources up to a factor of 7. This module excludes in the deconvolution process the IBIS/ISGRI detector pixels corresponding to the projection of a bright source through mask elements affected by some defects. These defects are most likely associated with screws and glue fixing the IBIS mask to its support. Following these major improvements introduced in OSA 9, a second order correction is still required to further remove the residual noise, now at a level of 0.2-1% of the brightest source in the field of view. In order to improve our knowledge of the IBIS mask transparency, a calibration campaign has been carried out during 2010-2012. We present here the analysis of these data, together with archival observations of the Crab and Cyg X-1, that allowed us to build a composite image of the mask defects and to investigate the origin of the residual noise in the IBIS/ISGRI images. Thanks to this study, we were able to point out a simple modification of the ISGRI analysis software that allows to significantly improve the quality of the images in which bright sources are detected at the edge of the field of view. Moreover, a refinement of the area excluded by the ghost busters module is considered, and preliminary results show improvements to be further tested. Finally, this study indicates further directions to be investigated for improving the ISGRI sensitivity, such as taking into account the thickness of the screws in the mask model or studying the possible discrepancy between the modeled and actual mask element bridges.

preprint2013arXiv

The IBIS / ISGRI Source Location Accuracy

We present here results on the source location accuracy of the INTEGRAL IBIS/ISGRI coded mask telescope, based on ten years of INTEGRAL data and on recent developments in the data analysis procedures. Data were selected and processed with the new Off-line Scientific Analysis pipeline (OSA10.0) that benefits from the most accurate background corrections, the most performing coding noise cleaning and sky reconstruction algorithms available. We obtained updated parameters for the evaluation of the point source location error from the source signal to noise ratio. These results are compared to previous estimates and to theoretical expectations. Also thanks to a new fitting procedure the typical error at 90% confidence level for a source at a signal to noise of 10 is now estimated to be 1.5 arcmin. Prospects for future analysis on the Point Spread Function fitting procedure and on the evaluation of residual biases are also presented. The new consolidated parameters describing the source location accuracy that will be derived in the near future using the whole INTEGRAL database, the new fitting technique and the bias correction, will be included in future versions of OSA.

preprint2003arXiv

In flight calibration of the ISGRI camera

ISGRI, the IBIS low energy camera (15 keV - 1 MeV) on board INTEGRAL, is the first large CdTe gamma-ray imager in orbit. We present here an overview of the ISGRI in-flight calibrations performed during the first months after launch. We discuss the stability of the camera as well as the CdTe pixels response under cosmic radiation. The energy calibra tions were done using lead and tungsten fluorescence lines and the $\mathrm{^{22}Na}$ calibration unit. Thermal effects and charge correction algorithm are discussed, and the resulting energy resolution is presented. The ISGRI background spatial and spectral non-uniformity is also described, and some image correction results are presented.