Source author record

A. Gafarov

A. Gafarov appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2023arXiv

Primary Cosmic Rays Energy Spectrum and Mean Mass Composition by the Data of the TAIGA Astrophysical Complex

The corrected dependence of the mean depth of the EAS maximum $X_{max}$ on the energy was obtained from the data of the Tunka-133 array for 7 years and the TAIGA-HiSCORE array for 2 years. The parameter $\langle\ln A\rangle$, characterizing the mean mass compositon was derived from these results. The differential energy spectrum of primary cosmic rays in the energy range of $2\cdot 10^{14}$ - $2\cdot 10^{16}$\,eV was reconstructed using the new parameter $Q_{100}$ the Cherenkov light flux at the core distance 100 m.}

preprint2022arXiv

Combinative Isobaric Resonances CIRs by MSS and from previous precise data

The elastic scattering {12}^C(p,p{o}_) Excitation Function (EF) was measured in the energy range Ep =16 - 19.5 MeV with resolution about 10 keV by means of innovative approach - MSS - the Method of Spectra Superposition at the 14-angle Magnetic Spectrograph (Apelsin) at beam with an energy spread of about 200 keV from U-150 cyclotron of INP Ulugbek (Tashkent) of Science Academy of Uzbekistan [1-9]. The obtained EF has a reach structure of anomalies in precise agreement with thresholds and levels data [2,10-12]. Measurements were done on the {12}^C self-supporting target with thickness 13 mg/cm2 and an area of 1 cm2 in the center of Apelsin. The 20-step Energy Moderator controlled the proton energy, providing a 3.5 MeV wide Ep interval with no readjustment of cyclotron and all the ionic-optics on the 41-meter-long beam-pipe. Energy resolution of Apelsin for protons is better than 5 keV. The spectrograph magnetic field was stabilized to 3ppm by NMR-monitor system [1,9]. The EF of {12}^C (p,p{o}_) scattering has many resonances that precisely correspond to g.s. and levels of well-known product-nuclei. But 80% of anomalies were not decoded. A new concept of Combinative Isobaric Resonance (CIRs) proposed to identify these anomalies. The proposed CIRs concept worked very promising (Fig. 4). To prove CIRs validity, precise excitation function of {12}^C(p,p{o}_), {12}^C(d,d{o}_), and {7}^Li(p,p{o}_), were analyzed in search for the Combinative Isobaric Resonances. This study perfectly proves existence of CIRs.

preprint2022arXiv

The Tunka-Grande scintillation array: current results

The Tunka-Grande experiment is a scintillation array with about 0.5 sq.km sensitive area at Tunka Valley, Siberia, for measuring charged particles and muons in extensive air showers (EASs). Tunka-Grande is optimized for cosmic ray studies in the energy range 10 PeV to about 1 EeV, where exploring the composition is of fundamental importance for understanding the transition from galactic to extragalactic origin of cosmic rays. This paper attempts to provide a synopsis of the current results of the experiment. In particular, the reconstruction of the all-particle energy spectrum in the range of 10 PeV to 1 EeV based on experimental data from four observation seasons is presented.

preprint2012arXiv

Detailed Report of the MuLan Measurement of the Positive Muon Lifetime and Determination of the Fermi Constant

We present a detailed report of the method, setup, analysis and results of a precision measurement of the positive muon lifetime. The experiment was conducted at the Paul Scherrer Institute using a time-structured, nearly 100%-polarized, surface muon beam and a segmented, fast-timing, plastic scintillator array. The measurement employed two target arrangements; a magnetized ferromagnetic target with a ~4 kG internal magnetic field and a crystal quartz target in a 130 G external magnetic field. Approximately 1.6 x 10^{12} positrons were accumulated and together the data yield a muon lifetime of tau_{mu}(MuLan) = 2196980.3(2.2) ps (1.0 ppm), thirty times more precise than previous generations of lifetime experiments. The lifetime measurement yields the most accurate value of the Fermi constant G_F (MuLan) = 1.1663787(6) x 10^{-5} GeV^{-2} (0.5 ppm). It also enables new precision studies of weak interactions via lifetime measurements of muonic atoms.

preprint2010arXiv

Measurement of the Positive Muon Lifetime and Determination of the Fermi Constant to Part-per-Million Precision

We report a measurement of the positive muon lifetime to a precision of 1.0 parts per million (ppm); it is the most precise particle lifetime ever measured. The experiment used a time-structured, low-energy muon beam and a segmented plastic scintillator array to record more than 2 x 10^{12} decays. Two different stopping target configurations were employed in independent data-taking periods. The combined results give tau_{mu^+}(MuLan) = 2196980.3(2.2) ps, more than 15 times as precise as any previous experiment. The muon lifetime gives the most precise value for the Fermi constant: G_F(MuLan) = 1.1663788 (7) x 10^-5 GeV^-2 (0.6 ppm). It is also used to extract the mu^-p singlet capture rate, which determines the proton's weak induced pseudoscalar coupling g_P.