Source author record

A. B. Laptev

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

4works
3topics
4close collaborators

Published work

4 publications

preprint2014arXiv

A Time Projection Chamber for High Accuracy and Precision Fission Cross Section Measurements

The fission Time Projection Chamber (fissionTPC) is a compact (15 cm diameter) two-chamber MICROMEGAS TPC designed to make precision cross section measurements of neutron-induced fission. The actinide targets are placed on the central cathode and irradiated with a neutron beam that passes axially through the TPC inducing fission in the target. The 4ππ acceptance for fission fragments and complete charged particle track reconstruction are powerful features of the fissionTPC which will be used to measure fission cross sections and examine the associated systematic errors. This paper provides a detailed description of the design requirements, the design solutions, and the initial performance of the fissionTPC.

preprint2013arXiv

Improved Determination of the Neutron Lifetime

The most precise determination of the neutron lifetime using the beam method was completed in 2005 and reported a result of τn=(886.3±1.2[stat]±3.2[syst])τ_n = (886.3 \pm 1.2 [\textrm{stat}] \pm 3.2 [\textrm{syst}]) s. The dominant uncertainties were attributed to the absolute determination of the fluence of the neutron beam (2.7 s). The fluence was measured with a neutron monitor that counted the neutron-induced charged particles from absorption in a thin, well-characterized 6Li deposit. The detection efficiency of the monitor was calculated from the areal density of the deposit, the detector solid angle, and the evaluated nuclear data file, ENDF/B-VI 6Li(n,t)4He thermal neutron cross section. In the current work, we have measured the detection efficiency of the same monitor used in the neutron lifetime measurement with a second, totally-absorbing neutron detector. This direct approach does not rely on the 6Li(n,t)4He cross section or any other nuclear data. The detection efficiency is consistent with the value used in 2005 but was measured with a precision of 0.057 %, which represents a five-fold improvement in the uncertainty. We have verified the temporal stability of the neutron monitor through ancillary measurements, allowing us to apply the measured neutron monitor efficiency to the lifetime result from the 2005 experiment. The updated lifetime is τn=(887.7±1.2[stat]±1.9[syst])τ_n = (887.7 \pm 1.2 [\textrm{stat}] \pm 1.9 [\textrm{syst}]) s.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.