On the quantization accuracy of the acoustoelectric current

preprint2008arXivOpen access

Abstract

By deriving analytical formulae for the quantization accuracy of the acoustoelectric current, we reveal that: 1) the flatness of the current plateau for the typical present devices has reached the theoretical limit of about 100ppm over a 1/1000 change of the gate voltage; 2) increasing the transport channel length, and counterintuitively, increasing the acoustic wavelength as well, would improve the quantization accuracy, and very promisingly up to 0.01ppm as required for a quantum current standard.

Explore this paper’s authors, topics and related work.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Reviews 0

Write a reviewWrite

No reviews yet.

Discussion 0

Add a commentWrite

No comments yet.