The step and impulse responses of a proper, rational transfer function are well-behaved analytic functions. We prove that such a response cannot have an inflection point such that the tangent at that point is parallel to the time-axis. Hence when a step or impulse response of a finite-dimensional LTI system crosses any given level, that crossing must be transversal, and can never be tangential.