Abstract
We report on measurements performed at low temperatures on a nanoelectromechanical system (NEMS) under (capacitive) parametric pumping. The excitations and detection schemes are purely electrical, and enable in the present experiment the straightforward measurement of forces down to about a femtonewton, for displacements of an Angström, using standard room temperature electronics. We demonstrate that a small (linear) force applied on the device can be amplified up to more than a 100 times, while the system is {\it truly moving}. We explore the dynamics up to about 50nm deflections for cantilevers about 200nm thick by 3m long oscillating at a frequency of 7MHz. We present a generic modeling of nonlinear parametric amplification, and give analytic theoretical solutions enabling the fit of experimental results. We finally discuss the practical limits of the technique, with a particular application: the measurement of {\it anelastic damping} in the metallic coating of the device with an exceptional resolution of about 0.5\%.
Connections
Explore this paper’s authors, topics and related work.
Building this map preview
BZPEER is loading the nearby papers, people, topics and institutions for this page.
Reviews 0
Write a review
No reviews yet.
Discussion 0
Add a comment