Abstract
In this study the Leidenfrost temperature during spray cooling of very hot substrates is experimentally measured. The spray parameters, i.e. the drop diameters and velocities and the mass flux, are very accurately measured. Astonishingly, the measured Leidenfrost temperature is independent of any of the spray impact parameters, but is determined exclusively by the materials of the liquid and the substrate. The mechanism of film boiling is explained by the formation of a fast propagating vaporizing front, when the inertial forces in the associated liquid flow are comparable with the viscous stresses. This leads to a theoretical prediction for the Leidenfrost temperature which agrees well with the experimental data.