Improving LIGO calibration accuracy by using time-dependent filters to compensate for temporal variations

The response of the Advanced LIGO interferometers is known to vary with time [arXiv:1608.05134]. Accurate calibration of the interferometers must therefore track and compensate for temporal variations in calibration model parameters. These variations were tracked during the first three Advanced LIGO observing runs, and compensation for some of them has been implemented in the calibration procedure. During the second observing run, multiplicative corrections to the interferometer response were applied while producing calibrated strain data both in real-time and in high-latency. In a high-latency calibration produced after the second observing run and during the entirety of the third observing run, a correction involving updating filters was applied to the calibration -- the time dependence of the coupled cavity pole frequency $f_{\rm cc}$. This paper describes the methods developed to compensate for variations in the interferometer response requiring time-dependent filters, including variable zeros, poles, gains, and time delays. The described methods were used to provide compensation for well-modeled time dependence of the interferometer response, which has helped to reduce systematic errors in the calibration to $<2$% in magnitude and $<2^{\circ}$ in phase across LIGO&#39;s most sensitive frequency band of 20 - 2000 Hz [arXiv:2005.02531, arXiv:2107.00129]. Additionally, this paper shows how such compensation is relevant for astrophysical inference studies by reducing uncertainty and bias in the sky localization for a simulated binary neutron star merger.

preprint2023arXivOpen access
0citations
0reviews
0saves
Nocode
Nodataset
0institutions

Next steps

Decide what to do with this paper

Use like or dislike for the fast social read. The more specific scholarly feedback stays available below when needed.

Log in to curate

Reading frame

Keep the important context close to the paper

Keep the important signals around this paper in one place: votes, save state, collection context, reviews and the metadata you need before deciding what to do next.

Institutions

Add specific reaction

Move through the context

Research map

Open full explorer

Move through nearby people, institutions, topics and adjacent work without leaving the paper page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Structured reviews

0 review(s)

ContributeLeave structured feedbackUse the review template when you have a concrete strength, concern or method question.Open review form

No structured reviews yet. High-signal critique starts here.

Work discussion

0 comment(s)

DiscussAdd a high-signal commentKeep quick notes, caveats and replication pointers separate from formal reviews.Open comment form

No discussion yet. The first strong comment sets the tone.