Data center energy efficiency enhancement using a two-phase heat sink with ultra-high heat transfer coefficient

This paper presents the latest progress on characterization of our membrane assisted phase-change heat sink (MHS) at conditions suitable for implementation in data centers (DCs). Experiments are conducted using water as the working fluid at a vapor space pressure ($P_{vapor}$) of 16 kPa, corresponding to a saturation temperature of $\sim$ 55$^{\circ}$C. This temperature is sufficiently lower than the silicon junction temperature of ~80$^{\circ}$C. As anticipated, the overall performance of MHS at sub-atmospheric pressure is lower compared to analogous tests at atmospheric pressure. In agreement with previous studies on MHS, the critical heat flux limit (CHF) increases with enhancement of the heat transfer area ratio ($A_r$) and liquid space pressure ($P_{pool}$). We report a maximum CHF of 670 W/cm$^2$ on a surface with an enhanced area ratio of 3.45, multiple times greater than the CHF reported hitherto by a comparable two-phase heat sink in literature. Heat transfer coefficients (HTC) as high as $\sim$ 1 MW/m$^2$-K are obtained. These record performance data along with unique characteristics of the MHS promise to greatly benefit next generation highly energy efficient DCs.

preprint2022arXivOpen access
0citations
0reviews
0saves
Nocode
Nodataset
0institutions

Next steps

Decide what to do with this paper

Use like or dislike for the fast social read. The more specific scholarly feedback stays available below when needed.

Log in to curate

Reading frame

Keep the important context close to the paper

Keep the important signals around this paper in one place: votes, save state, collection context, reviews and the metadata you need before deciding what to do next.

Institutions

Add specific reaction

Move through the context

Research map

Open full explorer

Move through nearby people, institutions, topics and adjacent work without leaving the paper page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Structured reviews

0 review(s)

ContributeLeave structured feedbackUse the review template when you have a concrete strength, concern or method question.Open review form

No structured reviews yet. High-signal critique starts here.

Work discussion

0 comment(s)

DiscussAdd a high-signal commentKeep quick notes, caveats and replication pointers separate from formal reviews.Open comment form

No discussion yet. The first strong comment sets the tone.